International Journal of Contemporary Pediatrics

Krishnan GR et al. Int J Contemp Pediatr. 2020 Jun;7(6):1225-1231

http://www.ijpediatrics.com

pISSN 2349-3283 | eISSN 2349-3291

Endtidal carbonmonoxide and carboxyhemoglobin for prediction of significant hyperbilirubinemia in healthy Indian neonates >35 weeks of gestation

Gokul Krishnan R.1*, Mangalabharathi S.2, Mohammed Sajjid2, Ramya S.3


1Department of Pediatrics, Narayana Medical College, Chinthareddypalem, Nellore, Andhra Pradesh, India

2Department of Neonatology, Institute of Obstetrics and Gynaecology, Madras Medical College, Chennai, Tamil Nadu, India

3Department of Neonatology, Institute of Child Health, Madras Medical College, Chennai, Tamil Nadu, India

Received: 01 May 2020

Accepted: 06 May 2020

*Correspondence:

Dr. Gokul Krishnan R.,

E-mail: drgokulkrishnan86@gmail.com

Copyright: © the author(s), publisher and licensee Medip Academy. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

ABSTRACT

Background: Endtidalcarbonmonoxide (ETCOc) and Carboxyhemoglobin (COHB) levels correlate well to bilirubin production and an availability of non-invasive point of care (POC) device in predicting significant hyperbilirubinemia is of great advantage when compared to measurement of serum bilirubin. Objective of the study is to measure a value of ETCOc and COHB in the early neonatal period for the prediction of significant hyperbilirubinemia.

Methods: This was the descriptive Cross Sectional Study. ETCOc and COHB were measured 12th hourly for 72 hours followed by TSB in whom the TCB was >14mg/dl. Neonates were classified as jaundiced whose TSB values were in phototherapy range as per AAP Recommendations. Receiver Operative Curves (ROC) were created by appropriate statistical software for ETCOc and COHb to predict significant hyperbilirubinemia. The Sensitivity, Specificity, Positive predictive value, Negative predictive value and likelihood ratios of each was determined and the correlation between ETCOc and COHb levels, ETCOc and TCB, COHB and TCB at different hours of age was evaluated.

Results: Among the total 320 infants, 156 of them developed significant hyperbilirubinemia. The ETCOc and COHB level at 60 hours of age was the most predictive of significant hyperbilirubinemia by ROC analysis. ETCOc cut-off of 1.65 ppm at 60 hours of age has a sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio and negative likelihood ratio of 84.6%, 80.5%, 80.5% and 84.6%, 4.33 and 0.19. COHB cut-off of 1.32 ppm at 60 hours of age has a sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio and negative likelihood ratio of 84.6%, 81%, 80% and 84.2%, 4.34 and 0.19.ETCOc had a maximum correlation with COHB at 48 hours of age.

Conclusions: An increased level of Endtidalcarbonmonoxide and Carboxyhemoglobin in the early neonatal period is useful as a screening test for prediction of significant hyperbilirubinemia.

Keywords: Carboxyhemoglobin, Early neonatal period, Endtidalcarbonmonoxide corrected, Hyperbilirubinemia

INTRODUCTION

Jaundice is one among the most common conditions requiring medical care in newborn babies. During the first week of life, more than 60% of healthy full term and 80% of preterm newborns develop hyperbilirubinemia. However, approximately 5% to 10% of neonates develop severe hyperbilirubinemia, defined as having total serum bilirubin (TSB) above 95th centile for age in hours, that requires phototherapy.1-3 Bilirubin production rate can be estimated by measuring the breath Carbonmonoxidelevels and Carboxyhemoglobin levels measured by Masimo Radical-7 monitor. The endtidalcarbonmonoxide (ETCOc) and Carboxyhemoglobin (COHB) levels correlate well to bilirubin production in neonates in the absence of pulmonary dysfunction. Having a non-invasive point of care (POC) device in predicting significant hyperbilirubinemia is of great advantage when compared to measurement of serum bilirubin by invasive method.

As such there are no Indian studies till date on the measurement of Endtidalcarbonmonoxide (ETCOc) and Carboxyhemoglobin (COHB) levels by non-invasive method to predict significant hyperbilirubinemia in healthy neonates. This study is designed to estimate the values of ETCOc and COHB in predicting significant hyperbilirubinemia.

METHODS

This descriptive study was conducted from October 2015 to March 2016 in the Intramural unit, Department of Neonatology, Madras Medical College, Chennai after obtaining clearance from the Institutional Ethics Committee. Sample size was calculated with Sensitivity of ETCOc and COHb in previous study (Okuyama et al,) of 86%. Precision (d) kept as 5%. By using (4PQ/d2 x Prevalence) formula minimum required sample is 320, were P= Sensitivity, Q =100-P. Subjects were recruited from amongst the live born infants delivered in Institute of Obstetrics and Gynaecology.

Inclusion criteria

  • • Gestational age more than 35 weeks.
  • • Appropriate for Gestational age and Small for gestational age babies.
  • • Enrolled in the study in first 12 hrs of life.

Exclusion criteria

  • • Neonates with major congenital malformations.
  • • Neonates requiring NICU admission.
  • • Neonates born to mothers with H/o. maternal smoking.

Parents of subjects who satisfy eligibility criteria were approached for participation in the study and were provided information about the study. After obtaining written informed consent from a parent, the baby was enrolled. Endtidalcarbonmonoxide (ETCOc) and Carboxyhemoglobin (COHb) levels of all babies who met the inclusion criteria were measured every 12 hrs during the first 72 hrs of life in healthy, Indian infants >35 week of gestation using a breath carbonmonoxide analyzer (PICO+) and Masimo monitor. In this study, the endtidalcarbonmonoxide was measured using a mask fitted to the carbon monoxide breath analyzer and carboxyhemoglobin (COHB) was measured non-invasively using Masimo radical-7 monitor. Bilirubin will be measured by Transcutaneousbilirubinometer (TCB) in babies at 24, 48, 72, 120 hrs and day 7 of life. Under strict aseptic precautions blood samples for TSB will be collected by venepuncture in babies whose TCB values are more than 14mg/dl.

Neonates who develop significant jaundice requiring phototherapy as per AAP Guidelines will be included in the test while, Neonates will be qualified as control subjects if their TSB levels were not in phototherapy range as per AAP recommendations.

Measurement

Endtidalcarbonmonoxide determination will be done with PICO+ carbonmonoxide breath analyzer, a hand-held portable device and Carboxyhemoglobin values will be measured by non-invasive method using Masimo Radical - 7 monitor. All measurement were performed with the same device by investigator according to the manufacturer’s instructions and the standard described technique. The ETCOc and COHb values of Hyperbilirubinemic babies at which phototherapy is initiated was assessed for the prediction of significant hyperbilirubinemia.

Laboratory measures

Blood will be collected by venepuncture in babies who develop significant jaundice requiring phototherapy. The bilirubin estimation was done by Photospectrometric bilirubin analyzer (Bili-Micro Meter, Kohsoku Denki Co Ltd, Tokyo, Japan). The micro-capillary tube containing the blood sample was blocked at one end and centrifuged at 12000 rpm for 5 minutes in a micro centrifuge to separate the serum. The processed micro capillary tube was fixed on to the holder of spectrometric bilirubin analyzer ensuring the serum column covered the entered length of the slit through which the light passes. A microprocessor converts the light intensity received by photodetector into the total bilirubin value which is digitally displayed. This method for estimation of bilirubin is simple, requires no reagents and needs only 50-70 µL of blood.

Statistical analysis

Data was recorded in a predesigned Performa analysed with appropriate statistical methods and percentile curves was drawn for observed values. Percentile charts and Receiver Operative Characteristic (ROC) curve was created by appropriate statistical software for ETCOc and COHb levels to predict significant hyperbilirubinemia. The Sensitivity, Specificity, Positive predictive value, Negative predictive value and likelihood ratios of each was determined.

The ROC curves of ETCOc and COHB at different ages between 12 to 72 hrs after birth was constructed and an optimal cut-off point was chosen by determining the nearest point on the ROC Curve to the left upper corner, where the expected benefit is maximum. The correlation coefficient between ETCOc and COHb levels, ETCOc and TCB, COHB and TCB at different hours of life was evaluated.

Figure 1: Flow of participants.
Figure 1: Flow of participants.

RESULTS

Among the neonates delivered during the study period, 507 babies met the eligibility criteria. Of them, 187 babies were excluded. Out of excluded babies, ninety one neonates were admitted in NICU; eleven of them were born with congenital anomalies and twenty three of them were excluded as there was h/o passive maternal smoking. Sixty two babies were excluded in view of denial of consent (Figure 1).

Finally 320 neonates were enrolled in the study. 156 neonates developed jaundice and 164 of them did not develop significant jaundice. None of the subjects were lost to follow up and data of all 320 subjects were collected and analyzed.

Description of baseline characteristics

The demographic profile and baseline maternal characteristics are summarized. 66 (20.6%) of the mothers had gestational diabetes mellitus and 41 (12.8%) of them had pregnancy induced hypertension. Oxytocin was used to augment labour in 11.5% mothers (37/320). Nearly half of the mothers were primigravida (50.9%) (163/320).

Males constituted 52.8% (169/320). 257 (80.3%) neonates were born by caesarean section and the remainder (n=63) by vaginal route (19.7%). 42 subjects were between 35 to 37 weeks of gestation which constituted around 13.1%. The birth weight of vast majority babies in the study group were between 2500 to 2999 grams.

Comparison of baseline variables in both groups

The baseline variables were balanced among the two groups. There was no statistical difference between jaundiced and non-jaundiced babies regarding gestational age (p value=0.58); birth weight (p value=0.54), sex ratio (p value=0.55) and Mode of delivery (vaginal: 21.2 vs. 18.3 % respectively, cesarean section: 78.8% vs. 81.7% respectively) (Table 1).

Table 1: Baseline neonatal characteristics.
Table reproduced from source PDF page 3
Table 2: Risk factors for neonatal hyperbilirubinemia.
Table reproduced from source PDF page 4
Table 3: Cut-off values, sensitivity, specificity, PPV, NPV and LR for ETCOc at different postnatal ages.
Table reproduced from source PDF page 4
Table 4: Cut-off values, sensitivity, specificity, PPV, NPV and LR for COHB at different postnatal ages.
Table reproduced from source PDF page 4

The common risk factors for jaundice like cephalhematoma, bruising, ABO incompatibility, Rh incompatibility and h/o jaundice in the previous sibling were evaluated. 17.3% (27/156) of subjects with cephalhematoma and 12.8% (20/156) of subjects with bruising developed significant jaundice (p<0.003). When both the risk factors (cephalhematoma and bruising) were present, the risk for subsequent jaundice was 100%, with a highly significant (p value <0.001). 12.8% (20/156) who developed jaundice were Rh incompatibility subjects (p=0.006) and H/o. jaundice in previous sibling was a major risk factor development of jaundice (p<0.001) (Table 2).

Prediction of significant hyperbilirubinemia

The ROC Curve for Endtidalcarbonmonoxide at 60 hours of age has a maximum area under curve of 0.87 (CI: 0.83-0.91) with a cut-off value of 1.65 ppm at 60 hours of age (Figure 2). The sensitivity, specificity, Positive predictive value and Negative predictive value were 84.6%, 80.5%, 80.5% and 84.6% (Table 3).

Similarly, the ROC curve for Carboxyhemoglobin measurements showed a maximum area under curve 0.87 (CI: 0.83-0.91). At a cut-off value of 1.32 ppm at 60 hours of life (Figure 3). The sensitivity, Specificity, Positive predictive value and Negative predictive value was 84.6%, 81%, 80% and 84.2%. The positive and Negative Likelihood ratio was 4.34 and 0.19 (Table 4).

Correlation between ETCOC, COHB and TCB

EndtidalCarbonmonoxide was found to correlate well with Carboxyhemoglobin at different postnatal ages with correlation co-efficient of 0.99 and highly significant p value (p<0.001). Correlation between endtidalcarbonmonoxide and carboxyhemoglobin is best at 48 hours of age. Correlation between endtidalcarbonmonoxide (ETCOc) and Transcutaneous bilirubin (TCB) is best at 72 hours of age with correlation co-efficient of 0.64 and a highly significant (p value

<0.001).The Correlation co-efficient between Carboxyhemoglobin (COHB) and Transcutaneous bilirubin (TCB) is 0.63 and best at 72 hours of age with a highly significant (p value <0.001).

Figure 2: ROC curve for ETCOc for different hours.
Figure 2: ROC curve for ETCOc for different hours.
Figure 3: ROC curve for COHB for different hours.
Figure 3: ROC curve for COHB for different hours.

DISCUSSION

Three hundred and twenty neonates >35 weeks of gestation were enrolled in the study within twelve hours of age and were followed up for the next 72 hours. A value of endtidalcarbonmonoxide and carboxyhemoglobin at 60 hours of age was the best in prediction of significant hyperbilirubinemia. Correlation between ETCOc and COHB measurements were maximum at 48 hours of age.

Endogenous productionof carbonmonoxide have been measured with various methods since 1940s. Engel et al, have found an excellent correlation between endogenous production of carbonmonoxide and bilirubin production.4 Carbonmonoxide (CO) and biliverdin are produced in equimolar amounts and biliverdin is quantitatively reduced to bilirubin.5 The measurement of carbonmonoxidein breath or blood can be used as an index of heme degradation and bilirubin production.6 Studies conducted by National Institute of child Health and Human Development (NICHD) demonstrate the feasibility of estimating bilirubin production as measured by Carbonmonoxide in breath.7,8 Elevated levels of exhaled carbonmonoxide may be helpful in identifying infants who are producing large amounts of bilirubin via a hemolytic process. Endtidalcarbonmonoxide measurement may be of limited value in neonates whose mother smoked during pregnancy as the fetus receives exogenous carbonmonoxide through the placenta.9 After birth the neonate exhales carbonmonoxide which may cause false positive readings.

The endtidalcarbonmonoxide measurements have been shown to correlate well with pulmonary excretion of carbonmonoxide.10 Therefore, determination of endtidalcarbonmonoxide is preferred, because it is non-invasive, immediate, accurate and reliable when compared to other methods.

This study was conducted in a tertiary care maternity hospital in a developing country, which accounts to an annual delivery rate of fifteen thousand neonates. The prevalence of jaundice in this unit is 50-60 % in >35 weeks of gestation. This rate is comparable to the ones reported by most authors in literature, both across the country and beyond. The risk factors that cause jaundice in this unit resemble those widely reported in standard textbooks and in the published literature. Hence, authors expect that this results would be generalizable to other units.

There was no statistical significance between type of delivery, gestation, sex and development of significant hyperbilirubinemia. 71% of babies with cephalhematoma and 76.9% of babies with bruising developed significant hyperbilirubinemia (p value 0.003).Whenboth the risk factors (cephalhematoma and bruising) were present in the same baby, then all babies (100%) developed jaundice with a highly significant p value (0.001). Rh negative setting was found to be a significant risk factor for development of jaundice (p value 0.006). In a similar study done byUetani et al, hedemonstrated that the endtidalcarbonmonoxide values were significantly higher in babies who developed neonatal jaundice as a result of ABO incompatibility or Rh incompatibility.11

ROC curve analysis

In Okuyama et al, study endtidalcarbonmonoxide values were measured every 6th hourly during the first 72 hours of life.12 The endtidalcarbonmonoxide values at 42 hours of life was best in the prediction of significant hyperbilirubinemia with sensitivity, specificity, positive predictive value and negative predictive value of 86%, 80%, 40%, 97%. In this study, ETCOc values were measured every 12th hourly during the first 72 hours of life. The ROC curve at 60 hours of age was the most prominently shifted upwards and to the left with the maximum area under the curve. This means that the ETCOc values at 60 hours of age is the most predictive of significant hyperbilirubinemia. The cut-off point of 1.65 ppm at 60 hours of age providesreasonable high sensitivity, specificity, positive predictive value and negative predictive value (84.6%, 80.5%, 80.5% and 84.6%).

The ROC curve is a useful technique for describing a screening test and for ranking the merits of alternative tests, which was conducted to find the efficacy of measuring endtidalcarbonmonoxide for predicting significant hyperbilirubinemia. Like endtidalcarbonmonoxide, the carboxyhemoglobin value at 60 hours of age is the most predictive of significant hyperbilirubinemia. At the cut-off point of 1.32 ppm at 60 hours of age the sensitivity, specificity, positive predictive value and negative predictive value were 84.6%, 80.5%, 80.5% and 84.6%. The positive likelihood ratio was 4.34 and negative likelihood ratio was 0.19.

Schutzman DL et al, in his study showed Carboxyhemoglobin is useful in determining the etiology of severehyperbilirubinemia in haemolytic process.13 Carboxyhemoglobin (COHB) values correlate well with pulmonary excretion of carbonmonoxide for the estimation of bilirubin production.14 EndtidalCarbonmonoxide measurements were found to correlate well with Carboxyhemoglobin measurements at different postnatal ages. The correlation between ETCOc and COHB is maximum with measurements done at 48 hours of life with a highly significant p value. There exists a mild correlation between TCB with ETCOc and TCB with COHB measurements at different post-natal ages, with a maximum correlation observed with measurements done at 72 hours of life.

Clinical impact of the study was with the ETCOc measurements authors were able to predict the development of significant hyperbilirubinemia in late preterm and term infants. But the prediction was maximum at the time when jaundice would also become clinically apparent for detection. This limits its clinical utility in practice as an early tool for prediction of subsequent hyperbilirubinemia. In This study, Carboxyhaemoglobin measurements by Masimo pulse oximetry proved to be an excellent alternative non-invasive tool compared to ETCOc measurements which warranted a tight seal with face mask. The carboxyhaemoglobin measurements by pulse oximetry could also be monitored in real time unlike ETCOc and hence would be more useful for bedside monitoring in NICU.

It is common in day today practice to see large number of subjects with risk factors who were discharged early after birth, land up with serum bilirubin values in exchange levels on follow up, particularly those with hemolytic jaundice. Hence, ETCOc and COHB could be used to predict the development of significant hyperbilirubinemia in all high risk neonates before discharge.

CONCLUSION

To conclude, the endtidalcarbonmonoxide (ETCOc) and carboxyhemoglobin (COHB) results in this study showed that increased levels in the early neonatal period was associated with prediction of subsequent significant hyperbilirubinemia.

Funding: No funding sources

Conflict of interest: None declared

Ethical approval: The study was approved by the Institutional Ethics Committee

REFERENCES

  1. 1. Bhutani VK, Johnson LH, Keren R. Diagnosis and management of hyperbilirubinemia in the term neonate: for a safer first week. Pediatric Clini North Am. 2004 Aug;51(4):843-61.
  2. 2. Ebbesen F, Andersson C, Verder H, Grytter C, Pedersen‐bjergaard L, Petersen JR, et al. Extreme hyperbilirubinaemia in term and near‐term infants in Denmark. Acta Paediatr. 2005 Jan;94(1):59-64.
  3. 3. Manning D, Todd P, Maxwell M, Platt MJ. Prospective surveillance study of severe hyperbilirubinaemia in the newborn in the UK and Ireland. Arch Dis Child Fetal Neonat Edit. 2007 Sep 1;92(5):F342-6.
  4. 4. Engel R. Estimation of heme turnover and erythrocyte survival in man from clearance of bilirubin and from carbon monoxide production. Clin Res. 1969;17:325.
  5. 5. Landaw SA, Callahan EW, Schmid R. Catabolism of heme in vivo: comparison of the simultaneous production of bilirubin and carbon monoxide. J Clini Investigat. 1970 May 1;49(5):914-25.
  6. 6. Stevenson DK, Ostrander CE, Johnson JD. Effect of erythrocyte destruction on the pulmonary excretion rate of carbon monoxide in adult male Wistar rats. J Lab Clini Medi. 1979 Oct;94(4):649-54.
  7. 7. Vreman HJ, Stevenson DK, Oh W, Fanaroff AA, Wright LL, Lemons JA, et al. Semiportable electrochemical instrument for determining carbon monoxide in breath. Clini Chem. 1994 Oct 1;40(10):1927-33.
  8. 8. Stevenson DK, Vreman HJ, Oh W, Fanaroff AA, Wright LL, Lemons JA, et al. Bilirubin production in healthy term infants as measured by carbon monoxide in breath. Clini Chem. 1994 Oct 1;40(10):1934-9.
  9. 9. Herschel M, Karrison T, Wen M, Caldarelli L, Baron B. Evaluation of the direct antiglobulin (Coombs') test for identifying newborns at risk for hemolysis as determined by end-tidal carbon monoxide concentration (ETCOc); and comparison of the Coombs' test with ETCOc for detecting significant jaundice. J Perinatol. 2002 Jul;22(5):341-7.
  10. 10. Smith DW, Hopper AO, Shahin SM, Cohen RS, Ostrander CR, Ariagno RL, et al. Neonatal bilirubin production estimated from" end-tidal" carbon monoxide concentration. J Pediatr Gastroenterol and Nutrit. 1984;3(1):77-80.
  11. 11. Uetani Y, Nakamura H, Okamoto O, Yamazaki T, Vreman HJ, Stevenson DK. Carboxyhemoglobin measurements in the diagnosis of ABO hemolytic disease. Pediatr Int. 1989 Apr;31(2):171-6.
  12. 12. Okuyama H, Yonetani M, Uetani Y, Nakamura H. End‐tidal carbon monoxide is predictive for neonatal non‐hemolytic hyperbilirubinemia. Pediatr Int. 2001 Aug 22;43(4):329-33.
  13. 13. Schutzman DL, Gatien E, Ajayi S, Wong RJ. Carboxyhemoglobin levels as a predictor of risk for significant hyperbilirubinemia in African-American DAT+ infants. J Perinatol. 2016 May;36(5):386-8.
  14. 14. Ostrander CR, Cohen RS, Hopper AO, Cowan BE, Stevens GB, Stevenson DK. Paired determinations of blood carboxyhemoglobin concentration and carbon monoxide excretion rate in term and preterm infants. J Lab Clini Medi. 1982 Nov;100(5):745-55.