International Journal of Contemporary Pediatrics

Suman BK et al. Int J Contemp Pediatr. 2023 May;10(5):753-754

http://www.ijpediatrics.com

pISSN 2349-3283 | eISSN 2349-3291

Self-knotting of infant feeding tube in urethra in male child an unfortunate complication-case report

Bijay Kumar Suman*, Ram Jeewan Singh, Keerthana Bachala, Amit Kumar Sinha


Department of Paediatric Surgery, AIIMS Patna, Bihar, India

Received: 18 March 2023

Accepted: 13 April 2023

*Correspondence:

Dr. Bijay Kumar Suman,

E-mail: drsuman1011@gmail.com

Copyright: © the author(s), publisher and licensee Medip Academy. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

ABSTRACT

Urethral catheterisation is a common routine procedure. Knotting of infant feeding tube in genitourinary tract is a rare complication. Various methods have been used in the removal of a knotted catheter. The methods include gentle but sustained traction under general anaesthesia, open cystostomy and endoscopic retrieval.

Keyword: Catheterisation, Infant feeding tube, Self-knotting, Voiding cystourethrogram

INTRODUCTION

In children urethral catheterisation is a common routine procedure. It is usually done with infant feeding tube.1 However, the procedure is safe, complications have been reported, including trauma during catheterisation, haematuria, and tube knotting within the genitourinary tract.2 Self-knotting within the bladder is a rare complication. Removal of a knotted tube from the bladder can be a major challenge. We are reporting a case of 1-month-old male child with spontaneous knotting of infant feeding tube within the urethra.

CASE REPORT

A 1-month-old male child with history of dribbling of urine and excessive crying during micturition since birth was presented to our emergency. Antenatal ultrasound at last trimester was suggestive of bilateral hydroureteronephrosis with adequate liquors. Child was evaluated outside and bladder catheterization was done with 8F infant feeding tube. He was referred to our institution for further evaluation. On examination child was active, afebrile, abdomen soft, bladder was not palpable. External genitalia were normal in appearance, testis bilaterally descended in scrotum, per urethral catheter was in situ. Peri catheter leaking of urine was present. There was no evidence of hematuria, meatal injury, suprapubic distension, or suprapubic tenderness. Routine blood and urine investigations were within normal limits.

Figure 1 (A and B): X-ray of knotted catheter (red arrow) in the urethra], the knot at the distal end of catheter (yellow arrow).
Figure 1 (A and B): X-ray of knotted catheter (red arrow) in the urethra], the knot at the distal end of catheter (yellow arrow).

Abdominal ultrasound was suggestive of bilateral hydroureteronephrosis and thickened bladder wall with provisional diagnosis of posterior urethral valve. Our plan was voiding cystourethrogram (VCUG). During VCUG procedure there was difficulty in removal of feeding tube and resistance was felt. We advised x ray abdomen (KUB). The x ray film showed self-knotting of infant feeding tube in penile urethra (Figure 1 A, red arrow]. After applying topical lidocaine to the meatus with help of 2 ml syringe gentle traction was applied, which resulted in extraction of infant feeding tube. After removal of infant feeding tube, the knot was seen at the distal end [Figure 1 B, Yellow arrow]. Subsequently child voided normally. We kept child on regular follow up. First follow up after 2 weeks for VCUG. The VCUG was suggestive of posterior urethral valve. Child is on uroprophylaxis. Our planned is cystoscopy and transurethral posterior urethral valve fulguration.

DISCUSSION

Urinary catheterization used for both diagnostic and therapeutic purposes. The procedure is not free of complications. The most common complication is infection and urethral trauma. Self-knotting of infant feeding tube is a rare complication. The risk factors of spontaneous knotting of infant feeding tube due to the excessive insertion of tube, catheterization technique, physical properties of the tube, over-distended urinary bladder, bladder spasm, and child’s anatomy of genitourinary tract.3 The male urethral length at birth is about 5 cm and of female is about 2.2 cm. Normally urethral length increases to 8 cm by three years of age and to 17 cm by adulthood.4 During bladder catheterisation length should not exceed 5-6 cm in term or 2.5-5 cm in premature neonate.5 Self-knotting result from excessive intravesical catheter coiling, and tip of catheter can migrate through a coil that creating a knot. The complication can be prevented by passing the infant feeding tube gently. Whenever resistance felt during removal of catheter, self knotting of catheter must be suspected. The abdominal radiography and ultrasonography should be done to confirmed the knot. There are various methods used for removal of a knotted catheter like gentle but sustained traction under general anaesthesia, open cystostomy and endoscopic retrieval.6-8 The most commonly used method is gentle but sustained traction under general anaesthesia but it could be complicated by urethral trauma and urethral stricture.9 Open cystostomy method used to retrieve a tube knotted in the bladder. In our case the knotting of infant feeding tube was in the penile urethra, so we used topical lidocaine (local anaesthesia) to the meatus and gentle traction was applied. Constant gentle traction resulted in extraction of the feeding tube. After removal of catheter child voided normally. Child is on regular follow-up.

CONCLUSION

Urinary catheterization is not free of complications. Spontaneous knotting is a rare complication. During removal of catheter if resistance felt, self knotting of catheter must be suspected. The appropriate selection of catheter size, length, flexibility of catheter, proper technique of insertion, peculiar anatomy of neonates and infants helps to prevent this complication.

Funding: No funding sources

Conflict of interest: None declared

Ethical approval: Not required

REFERENCES

  1. 1. Sugar EC, Firlit CF. Knot in urethral catheter due to improper catheterization technique. Urology. 1983;22(6):673-4.
  2. 2. Arena B, McGillivray D, Dougherty G. Urethral catheter knotting: Be aware and minimize the risk. CJEM. 2002;4(2):108-10.
  3. 3. Singh VP, Sinha S. Spontaneous knotting of urinary catheters placed with nonindwelling intent: Case series and literature review. Urol Ann. 2019;11(4):443-6.
  4. 4. Smith AB, Adams LL. Insertion of indwelling urethral catheters in infants and children: a survey of current nursing practice. Pediatr Nurs. 1998;24(3):229-34.
  5. 5. Carlson D, Mowery BD. Standards to prevent complications of urinary catheterization in children: should and should-knots. J Soc Pediatr Nurs. 1997;2(1):37-41.
  6. 6. Gonzálvez Piñera J, Fernández Córdoba M, Vidal Company A. Intravesical knot of Foley catheter: Unusual complication of cystourethrography in children. An Esp Pediatr. 2000;53:601-3.
  7. 7. Mayer E, Ankem MK, Hartanto VH, Barone JG. Management of urethral catheter knot in a neonate. Can J Urol. 2002;9:1649-50.
  8. 8. Dogra PN, Nabi G, Goel R. Endoscopic removal of knotted urethral catheter: A point of technique. Urol Int. 2003;71:8-9.
  9. 9. Anbu AT. Urethral catheter knotting in preterm neonates. Indian Pediatr. 2004;41:631-2.