Review Article
Lymph node biopsy in resource-limited breast cancer systems: a scoping review of non-nuclear mapping, implementation and outcomes
Department of General Surgery, Victoria Mxenge Hospital, Durban, South Africa
Received: 03 September 2026
Accepted: 08 October 2026
*Correspondence:
Dr. Hridhay Somera,
E-mail: hridhaysomera@gmail.com
Copyright: © the author(s), publisher and licensee Medip Academy. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
ABSTRACT
This study aimed to map non-nuclear sentinel lymph node biopsy techniques for breast cancer in resource-limited systems and synthesise implementation requirements and outcomes. Scoping review following Joanna Briggs Institute guidance and PRISMA-ScR. Setting: Services meeting a service-level definition of resource limitation; low- or middle-income country location alone was insufficient. Information sources: PubMed, Europe PMC and backward citation searching. Subjects: Clinical studies, implementation reports, surveys, reviews and guidelines on axillary staging. Outcome measures: Identification, false-negative performance, morbidity, axillary dissection avoided, cost, barriers and training. The merged database exports contained 2,301 records; 1,252 unique records were screened and 36 evidence sources included. Methylene blue (MB) programmes reported 85.7%–100% identification, with a 13% false-negative rate in one meta-analysis. Fluorescein plus MB achieved 82%–100% identification with false-negative rates of 6.3%–8.7%. Indocyanine green series achieved 95.7%–100% identification but required near-infrared equipment. Gentian violet achieved 97.5% identification in a small cohort. Ethiopian programmes achieved 100% identification; one avoided axillary dissection in 80%. North African data showed less lymphoedema after sentinel biopsy than dissection (3.8% versus 23.0%). Constraints were nuclear medicine, pathology, supply, training and follow-up. Non-nuclear sentinel node biopsy appears feasible in resource-limited services when introduced as a governed pathway rather than dye substitution. MB was the lowest-cost/lowest-infrastructure option identified; fluorescein plus MB adds redundancy, while indocyanine green suits services able to support reusable imaging. Evidence is insufficient to establish oncological equivalence. Prospective implementation studies with audited recurrence, morbidity and cost are required.
Keywords: Breast cancer, Sentinel lymph node biopsy, Resource-limited settings, Methylene blue, Implementation science
INTRODUCTION
Breast cancer accounted for an estimated 2.3 million new diagnoses in 2022 and is now the most commonly diagnosed cancer in women. Its burden is rising across Sub Saharan Africa and South Asia, where population growth, epidemiological transition and uneven access to early diagnosis increase the number of women presenting to services that cannot deliver the full surgical pathway. In Sub Saharan Africa, advanced stage presentation is common and materially reduces the pool eligible for de-escalation, but it does not remove the obligation to provide accurate, low morbidity axillary staging for women who do present with clinically node-negative disease.1,2
Sentinel lymph node biopsy, or SLNB, replaced routine axillary lymph node dissection, or ALND, for clinically node-negative early breast cancer because it preserves staging information while reducing arm morbidity. Randomised evidence established equivalent survival after sentinel node resection in node negative disease and better quality of life than standard axillary treatment.3,4 The implementation gap is therefore not uncertainty about whether SLNB is beneficial. It is the failure of a complex service to reach patients when radiopharmaceuticals, gamma probes, pathology workflows and trained teams are unavailable.
This gap is large. In an eleven country survey, 67% of surgeons working in resource-limited settings reported no access to SLNB and 60% lacked immunohistochemistry.5 Resource-stratified frameworks recognise that safe care must be matched to available diagnostic, surgical, pathology and radiotherapy capacity, yet adoption of high-income country recommendations without those linked services can produce incomplete or unsafe care.6 A radioisotope is only one component of the problem: a low-cost dye cannot compensate for poor patient selection, absent pathology, no rescue plan after failed mapping, or unreliable follow-up.
A scoping review was selected because the evidence spans validation cohorts, implementation case series, surveys, training interventions, technology studies, guidelines and landmark trials, with substantial heterogeneity that precludes a single pooled effect estimate. The review follows PRISMA-ScR and contemporary scoping review guidance.7,8 Its objectives were to map non-nuclear tracers, infrastructure, barriers, training and outcomes; determine which combinations are scalable; and propose a staged implementation model for resource-limited breast cancer systems. The question is timely because isotope supply remains fragile, affordable fluorescence is maturing, and virtual training has expanded since the pandemic. To our knowledge, this is the first scoping review centred specifically on non-nuclear mapping as a health system intervention rather than a tracer accuracy question. It links technical performance to the pathology, adjuvant treatment and surveillance functions required for meaningful de-escalation.
METHODS
Protocol and reporting
An a priori protocol defined the population, concept and context, eligibility criteria, search, charting fields and narrative synthesis. The protocol was not externally registered. Reporting follows the PRISMA-ScR checklist, which is provided in Appendix II.
Eligibility criteria
The population was adults with breast cancer undergoing or being considered for SLNB, principally those with clinically node-negative early-stage disease. The concept comprised non-nuclear mapping, locally adapted nuclear pathways, infrastructure, cost, training, implementation barriers and clinical outcomes. The context was operationalised at service level. A study was considered resource-limited when the report documented at least one SLNB-relevant constraint, such as absent or unstable nuclear medicine or gamma-probe access, limited pathology capacity, tracer or device affordability or supply constraints, training or case-volume limitations, or unreliable follow-up, or when investigators explicitly described the service as resource-limited. Low- or middle-income country location alone was not sufficient. Borderline tertiary-centre reports were included only when an explicit SLNB-relevant constraint or resource adaptation was described. Landmark axillary trials and resource-stratified guidance were eligible as contextual evidence only when they directly informed omission of ALND or service design; they were not used to infer feasibility in resource-limited services. Primary clinical studies, systematic reviews, implementation reports, surveys, training evaluations and guidelines were included. Laboratory or animal studies, non-breast cancers, purely diagnostic imaging studies, reports without extractable implementation relevance, and non-English reports were excluded. No starting date was imposed. Evidence available through 24 August 2026 was considered.
Information sources and search strategy
PubMed and Europe PMC were searched on 24 August 2026. The electronic strategy combined controlled vocabulary and title or abstract terms for breast cancer and sentinel node biopsy with a third enrichment block covering named tracers, resource-setting terms and implementation concepts. Embase, Scopus/Web of Science and Cochrane databases were not searched. Because the enrichment block can miss SLNB reports whose titles or abstracts do not state a tracer, implementation issue or resource constraint, resource setting was assessed again at full-text eligibility and backward citation searching plus targeted journal-site searching was used to identify regional reports. The review should therefore be interpreted as a focused evidence map rather than an exhaustive bibliographic census. The complete reproducible strategy and source counts are in Appendix I.
Selection process
Records were deduplicated by DOI and normalised title. One reviewer screened titles and abstracts, retrieved potentially eligible reports, applied the eligibility criteria at full text and charted included studies. A second independent reviewer was not available; duplicate screening and duplicate charting were therefore not performed. Reasons for full-text exclusion were recorded in mutually exclusive categories. Selection is summarised in Figure 1.
Data charting
A piloted charting form captured country, setting, design, sample, clinical eligibility, tracer and injection method, comparator, identification rate, nodes retrieved, sensitivity, false-negative rate, complications, ALND avoided, follow-up, infrastructure, cost, training and implementation determinants. Numerical data were checked against the article abstract or full report. Where denominators differed between enrolled, mapped and analysable cohorts, the study denominator was retained and stated. Currency figures are reported as stated by investigators, with approximate United States dollar equivalents only where the source provided them. No inflation adjustment was attempted, so costs describe local affordability at the study time rather than present universal prices.
Critical appraisal and synthesis
Formal risk of bias appraisal was not performed because the purpose was to map evidence and implementation requirements rather than estimate a treatment effect. Evidence maturity was nevertheless made explicit by separating randomised or completion ALND validation studies from retrospective cohorts, training surveys, preclinical technology reports and a preprint. Results were synthesised descriptively across five domains: mapping performance; infrastructure and cost; barriers and facilitators; training; and clinical outcomes. Between study comparisons are interpretive because case mix, injection technique, neoadjuvant exposure, pathological reference standards and definitions differed.
RESULTS
Selection and evidence profile
The merged database exports contained 2,301 records. After 1,049 duplicates were removed, 1,252 unique records were screened and 1,070 were excluded at title/abstract screening. Of 182 database reports sought for retrieval, seven were not retrieved and 175 were assessed in full text. Five additional reports entered full-text assessment through other methods, giving 180 full-text reports assessed; 144 were excluded and 36 evidence sources were included (Figure 1). Table I lists all 36 included evidence sources (references 3-6 and 9-40). References 1-2 provide background epidemiology and references 7-8 provide reporting and methodological guidance and are not counted among the 36 included sources. The included evidence comprised clinical validation studies and programme series, two technology development reports, one training evaluation, an international service survey, systematic reviews, resource frameworks and landmark axillary trials. India generated most country-specific reports, while Sub-Saharan African evidence came from Ethiopia, Nigeria, Kenya and South Africa (Figure 2).
Methylene blue and programme feasibility
Methylene blue (MB) was the most frequently represented low-infrastructure technique in the included evidence and can use existing theatre instruments with an inexpensive, widely stocked dye. Across 18 studies, a meta-analysis estimated 91% identification but a 13% false-negative rate, above conventional acceptability thresholds.9 This pooled result is a necessary counterweight to selected programme estimates of 78% to 98% identification and 3% to 10% false-negative performance. High rates in experienced units should not be treated as proof that dye alone is intrinsically equivalent to dual mapping.
In Enugu, 24 of 28 patients had a sentinel node identified, giving 85.7% identification, 90.9% sensitivity and a 9.1% false-negative rate; identification improved from 78.6% in the first half of cases to 92.9% in the second.10 Indian and Indonesian cohorts reported identification of 95.9% and 97.6%, respectively.11,12 In Addis Ababa, all 20 patients had one to six nodes retrieved and 30% contained metastases, but all underwent completion ALND because frozen section and reliable adjuvant pathways were constrained.13 At St Paul’s Hospital, all 40 cases mapped successfully and 32 women, or 80%, avoided ALND after negative pathology.14 These two Ethiopian experiences show that technical success and therapeutic de-escalation are different implementation outcomes.
The Kenyan series reported 31 positive SLNBs among 129 women and a 5.1% regional recurrence rate among 79 followed beyond two years, while adjuvant treatment completion was incomplete.15 In South Africa, replacing the nuclear pathway with superparamagnetic iron oxide increased the proportion of eligible women receiving SLNB from 42% to 53%, but required a proprietary magnetometer.16 A Tunisian comparison found lymphoedema after SLNB in 3.8% versus 23.0% after ALND, with lower early pain and a shorter hospital stay.17 Thus access, morbidity and downstream treatment are at least as important as node detection.
Technique performance and cost
An Indian randomised study reported identification of 97.4% with methylene blue plus radioisotope and a 2.6% false-negative proportion, while a roughly 10 mL methylene blue vial cost about INR 15.18 Dye availability does not eliminate quality requirements. Deep parenchymal or peritumoral injection should be favoured over intradermal delivery when feasible because superficial methylene blue can cause skin staining or necrosis. Each programme needs a predefined failed mapping plan and an initial validation phase. Table II and Figure 3 compare the principal non-nuclear options.
Table 1 contains all 36 evidence sources included in the scoping review (Refs 3-6 and 9-40). Refs 1-2 provide background epidemiology and Refs 7-8 provide reporting/methodological guidance and are not counted among the 36 included sources. Landmark trials and resource-stratified guidelines in Table I are contextual evidence only and were not used to infer feasibility in resource-limited services. ALND, axillary lymph node dissection; BHGI, Breast Health Global Initiative; ICG, indocyanine green; MB, methylene blue; NACT, neoadjuvant chemotherapy; NPV, negative predictive value; SLNB, sentinel lymph node biopsy.
Fluorescein provides visible fluorescence using an inexpensive blue or ultraviolet light source. In a 65 patient validation study, fluorescein plus methylene blue identified nodes in 95.4% with a 6.3% false-negative rate, comparable with 97% and 6.3% for radioisotope plus methylene blue.19 A 130 patient randomised trial found identification of 89.0% versus 90.9%, establishing non inferiority within its prespecified margin; this corrects the occasionally repeated 84.6% estimate.20 A further validation cohort reported 96.7% identification and 7.4% false-negative results before chemotherapy, but only 82% identification after neoadjuvant treatment.21 Other prospective reports found 100% identification with a 7.1% false-negative rate and, separately, 96% detection, 96% sensitivity, 98% specificity and a 4.2% false-negative rate.22,23 A practical cost estimate for fluorescein, light source and methylene blue was INR 2,000, about US$23, although one randomized cost analysis reported INR 2,543 per successful procedure. These programme specific figures should not be transferred between health systems without local microcosting.
Indocyanine green, or ICG, offers real-time lymphatic visualisation without nuclear medicine. An Indian randomised trial found 100% identification with ICG plus methylene blue versus 91.4% with radioisotope plus methylene blue, but the ICG arm cost more when camera capital was included.24 A 207 patient comparison reported 97% identification with ICG plus methylene blue and 95% with radioisotope plus methylene blue, against a background decline in isotope availability.25 In a 100 patient prospective study, ICG alone identified 96% of nodes and had a 3.1% false-negative rate, while the dual dye comparator identified 94% with a 6.2% false-negative rate.26 A Tunisian series achieved 95.7% identification and observed no axillary recurrence at 29.2 months.27 Meta analytic evidence found no material detection difference between ICG and radioisotope, but heterogeneity was substantial.28 ICG therefore shifts rather than removes infrastructure: it avoids radioactive procurement but requires a maintained near infrared camera, trained staff, sterile draping and contingency for equipment failure.
Gentian violet and photoacoustic detection remain developmental. In 40 patients, gentian violet plus radioisotope identified 97.5% of sentinel nodes with a reported 2.5% false-negative rate and no short-term complications.29 Because the study was small, retrospective and radioisotope validated, gentian violet cannot yet be recommended as a standalone tracer. A handheld photoacoustic finder combines blue dye with optical excitation and ultrasound detection.30 In a prospective cross-sectional study it detected 87% of excised sentinel nodes, compared with 85% for a gamma probe and 73% for visual inspection, but sensitivity was 0.81 and specificity 0.63 against dual mapping.31 Ex vivo node assessment is proof of concept, not evidence for unsupervised clinical replacement.
Infrastructure, barriers and training
A minimum service requires reliable clinical and axillary ultrasound selection, sterile dye preparation, theatre lighting or a validated fluorescence device, specimen orientation, trained histopathology, a result communication pathway and longitudinal surveillance. Frozen section is helpful but not essential if a safe staged plan exists. Immunohistochemistry should be available for tumour biology, but routine cytokeratin staining of every sentinel node is not a prerequisite. Dyes need secure procurement, batch tracking and storage according to the manufacturer; most avoid the radiopharmaceutical cold chain, but ICG and fluorescein remain vulnerable to stock interruption and expired consumables.
The recurring barriers were high technology cost, isotope and tracer shortages, absent nuclear medicine, limited pathology, late presentation, insufficient case volume, no proctored training and weak follow-up. These are coupled constraints. For example, introducing mapping without adjuvant radiotherapy can invalidate treatment strategies that rely on breast irradiation, while introducing frozen section without reliable staffing may delay operations and waste specimens. Table III converts these barriers into measurable countermeasures.
Training evidence was limited. The BRIDGE course delivered seven hours of virtual teaching on resource adapted breast surgery, including methylene blue and a fluorescein torch. Among 66 post course respondents, at least 85% reported improved confidence across domains and 96% planned to adopt at least one technique, but competence and patient outcomes were not measured.32 In a 100 case single surgeon series using fluorescein plus methylene blue, identification reached 92% after case 20 and the false-negative rate remained below 7%.33 Virtual teaching should therefore prepare teams, not credential them. A sustainable pathway combines theory, a skills laboratory, proctored consecutive cases, validation against an audited reference standard, and service dashboards (Supplementary Figure 1). Oncoplastic breast surgery workshops can host this practical component because they already bring multidisciplinary teams together.
Clinical outcomes and evidence maturity
The strongest immediate benefit was avoidance of ALND and its morbidity. The St Paul’s cohort avoided ALND in 80%, and the Tunisian comparison showed an absolute 19.2 percentage point reduction in lymphoedema. Indian, Indonesian and Tunisian cohorts reported no axillary recurrence during relatively short follow-up, but sample sizes and surveillance completeness limit oncological inference. A Sri Lankan retrospective preprint reported 98.3% identification in 115 analysable patients, no isolated axillary recurrence among 75 sentinel negative women over a mean 36.3 months, and an estimated tracer cost near US$0.50.34 It is labelled as a preprint because peer review could alter those estimates. Another Indian programme achieved 100% localisation without a handheld gamma probe by coordinating SPECT CT, lymphoscintigraphy and methylene blue, but its mixed cancer cohort and 6.5% axillary recurrence signal underline the importance of disease specific audit.35 Supplementary Figure 2 summarises selected programme outcomes.
DISCUSSION
Summary and interpretation
This review found that non-nuclear SLNB is feasible in selected resource-limited services, but the evidence does not establish oncological equivalence of non-nuclear pathways across settings or justify replacing routine ALND without local validation and dependable downstream care. MB was the lowest-cost/lowest-infrastructure option identified in this review and had the broadest regional evidence, but its pooled false-negative rate remains the principal caution. Fluorescein plus MB offers redundancy for little consumable cost and an observable learning curve. ICG performs well and provides real-time anatomy, but camera purchase, maintenance and sterile integration can make it less affordable than its label suggests. Gentian violet and photoacoustic detection are promising research options, not current service standards.
Identification rate is a technical process measure, not a surrogate for oncological safety. A service may achieve high node identification while still having an unacceptable false-negative rate or unreliable downstream pathology, adjuvant treatment or follow-up. Claims about safe de-escalation therefore require evidence on false-negative performance, regional recurrence, morbidity, treatment completion and surveillance. These outcomes were inconsistently reported and were usually based on small cohorts with short follow-up in the included literature.
The implementation unit is the pathway. Earlier South African experience emphasised multidisciplinary planning, validation and local ownership rather than isolated technical transfer.36 At minimum, a programme must answer five questions before the first independent case: who is eligible; what happens if no node maps; how will nodes be processed and results communicated; when can ALND be omitted; and how will axillary recurrence and arm morbidity be detected? A tracer should be selected only after these questions are resolved.
Resource-stratified care
Resource-stratified frameworks from the Breast Health Global Initiative, WHO scenarios and the NCCN Framework are better interpreted as sequencing tools than permission for a lower standard.37 At a basic level, clinically node-negative patients may still receive ALND when pathology, safe mapping or follow-up is absent. At a limited level, methylene blue or fluorescein dual dye can be introduced with permanent section pathology and a planned second operation when needed. At an enhanced level, ICG or magnetic tracers, frozen section and structured survivorship surveillance become realistic. ASCO guidance defines which contemporary patients may omit SLNB or further axillary treatment, but those recommendations assume accurate imaging, tumour biology, radiotherapy and follow-up that cannot be taken for granted.38
Z0011 showed no survival detriment from omitting ALND in selected women with one or two positive sentinel nodes receiving breast conserving therapy and whole breast irradiation.39 AMAROS showed that axillary radiotherapy provides comparable control with less lymphoedema than ALND for sentinel node positive disease.40 These trials can reduce surgical burden only where their cointerventions are reproducible. Applying the nodal rule while omitting radiotherapy, systemic treatment or follow-up is not adaptation; it is partial adoption with uncertain oncological safety.
Authors’ proposed implementation framework
The framework below is a synthesis-derived proposal intended to support local planning; it has not been prospectively validated as a guideline. A hub-and-spoke model may be practical. A regional hub can provide pathology oversight, trainer accreditation, camera or magnetic device maintenance, procurement and outcome analysis, while district or provincial units perform carefully selected dye-guided cases. The first phase should establish baseline ALND volume, morbidity and pathway failures. The second should use proctored consecutive cases with completion ALND or another defensible reference standard during the learning phase. The authors propose 20–30 consecutive proctored validation cases as a pragmatic starting range; the lower bound is informed by the learning-curve report in which identification reached 92% after case 2033. The full 20–30 range is not a validated universal requirement. Likewise, an identification rate of at least 90% is presented only as a pragmatic local audit trigger, not as a surrogate for oncological safety or a universal credentialing standard. Programmes should predefine local criteria that also include acceptable false-negative performance, a failed-mapping plan, pathology reliability and follow-up. Subsequent spread should occur through trained teams rather than individual enthusiasts.
Audit should use denominators that expose implementation failure: the proportion of eligible patients offered SLNB; identification rate; number of sentinel nodes; conversion to ALND; nodal positivity; pathology turnaround; reoperation; seroma, infection, pain and lymphoedema; adjuvant treatment completion; loss to follow-up; and regional recurrence. Identification alone can look excellent while most eligible women never reach the procedure. Patient reported arm function and financial toxicity should be added because avoiding ALND has value only if savings and morbidity reduction reach patients.
Infrastructure and policy implications
Policy makers should fund SLNB as a bundled service rather than a dye line item. Procurement contracts should cover at least two approved tracers, light source or camera maintenance, emergency drugs for hypersensitivity, pathology consumables and data capture. Shared equipment can improve utilisation, but a camera that circulates between hospitals without scheduled maintenance or sterile accessories is not reliable capacity. Cold chain planning is essential for radiocolloid where retained; non-nuclear dyes simplify logistics but still need storage monitoring and predictable national registration.
Training should be competency-based. Short virtual courses are efficient for theory and can support tele-mentoring, case selection meetings and video review, especially where travel is expensive. They should be followed by simulation, direct proctoring and outcome-based credentialing. Regional oncoplastic workshops are a natural platform for injection practice, axillary anatomy, troubleshooting and specimen handling. Tele mentoring can extend expert reach, but connectivity, consent, data governance and the ability to intervene after a failed map must be designed in advance.
Limitations
The review is limited by heterogeneous designs, small single-centre cohorts, inconsistent outcome definitions and short follow-up. Completion ALND, the best available validation reference in many studies, exposes participants to the morbidity the programme seeks to avoid and was not uniformly used. Formal quality appraisal and meta-analysis were outside the scoping objective. One reviewer performed screening and charting and no duplicate review was available, increasing the risk of selection or extraction error. The bibliographic search was limited to PubMed and Europe PMC and English-language reports; Embase, Scopus/Web of Science and Cochrane were not searched. In addition, the third search block required a tracer, implementation or resource-related term, which may have missed relevant SLNB studies that did not signal resource constraints in titles or abstracts. Although the revised eligibility criteria use a service-level operational definition, heterogeneity between settings remains. Publication bias probably favours successful programmes, several estimates came from motivated specialist centres, and evidence from Francophone Africa, much of South Asia and rural services was sparse. The Sri Lankan report was a preprint and the newest gentian violet, fluorescein and photoacoustic reports require replication. High identification rates and technical feasibility should therefore not be interpreted as evidence of long-term oncological equivalence.
Future directions
Research should move from single-tracer accuracy to prospective implementation science. Priorities include multicentre validation of methylene blue plus fluorescein; pragmatic comparison with ICG where a reusable camera is already present; microcosting that includes capital depreciation, pathology, reoperation and patient travel; and registries with at least five years of axillary recurrence and patient-reported arm outcomes. Clustered studies should test hub-and-spoke training, tele-mentoring and procurement. Equity analyses should assess rural and neoadjuvant populations. Photoacoustic devices require in vivo workflow, clinically meaningful specificity and independent cost validation before scale-up.
CONCLUSIONS
Non-nuclear SLNB is feasible in selected resource-limited services, but current evidence does not establish oncological equivalence. MB was the lowest-cost/lowest-infrastructure option identified in this review; fluorescein plus MB may add redundancy, and ICG suits services with sustainable imaging. Safe adoption requires reliable pathology, local validation, failed-mapping plans and longitudinal audit. Longer-term multicentre outcomes are required before broad de-escalation.
Funding: No funding sources
Conflict of interest: None declared
Ethical approval: The study was approved by the Institutional Ethics Committee
REFERENCES
- 1. Bray F, Laversanne M, Sung H, Ferlay J, Siegel RL, Soerjomataram I, et al. Global cancer statistics 2022: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J Clin. 2024;74(3):229-63.
- 2. Jedy-Agba E, McCormack V, Adebamowo C, Dos-Santos-Silva I. Stage at diagnosis of breast cancer in sub-Saharan Africa: a systematic review and meta-analysis. Lancet Glob Health. 2016;4(12).
- 3. Krag DN, Anderson SJ, Julian TB, et al. Sentinel-lymph-node resection compared with conventional axillary-lymph-node dissection in clinically node-negative patients with breast cancer: overall survival findings from the NSABP B-32 randomised phase 3 trial. Lancet Oncol. 2010;11(10):927-33.
- 4. Mansel RE, Fallowfield L, Kissin M, et al. Randomized multicenter trial of sentinel node biopsy versus standard axillary treatment in operable breast cancer: the ALMANAC Trial. J Natl Cancer Inst. 2006;98(9):599-609.
- 5. Yadav SK, Sharma D, Sharma DB, Kintu-Luwaga R, Jha CK, Shekhar S. Barriers and challenges in providing standard breast cancer care in low resource settings. Trop Doct. 2022;52(4):532-7.
- 6. El Saghir NS, El Tomb PA, Carlson RW. Breast cancer diagnosis and treatment in low- and mid-resource settings: the role of resource-stratified clinical practice guidelines. Curr Breast Cancer Rep. 2018;10(3):187-95.
- 7. Tricco AC, Lillie E, Zarin W, O'Brien KK, Colquhoun H, Levac D, et al. PRISMA extension for scoping reviews (PRISMA-ScR): checklist and explanation. Ann Intern Med. 2018;169(7):467-73.
- 8. Peters MDJ, Marnie C, Tricco AC, et al. Updated methodological guidance for the conduct of scoping reviews. JBI Evid Synth. 2020;18(10):2119-26.
- 9. Li J, Chen X, Qi M, Li Y. Sentinel lymph node biopsy mapped with methylene blue dye alone in patients with breast cancer: a systematic review and meta-analysis. PLoS One. 2018;13(9).
- 10. Okoye CL, Ezeome ER. Use of methylene blue dye for lymphatic basin mapping and sentinel lymph node biopsy in breast cancer patients in Enugu, Nigeria. Niger J Clin Pract. 2022;25(11):1805-11.
- 11. Devarakonda S, Thomas SS, Sen S, Thomas V, Karuppusami R, Cherian AJ, et al. Sentinel lymph node biopsy in early breast cancer using methylene blue dye alone: a safe, simple, and cost-effective procedure in resource-constrained settings. Indian J Surg Oncol. 2021;12:210-17.
- 12. Hermansyah D, Rahayu Y, Azrah A, Pricilia G, Paramita D, Siregar ES, et al. Accuracy of methylene blue test as single technique for sentinel lymph node biopsy in early stages breast cancer. Asian Pac J Cancer Prev. 2021;22(9):2765-9
- 13. Getu Bekele P, Saha S, Thomas Malore E, Girma Mamo M, Demelash Gizachew S, Jemberu Robele T, et al. Preliminary results of sentinel lymph node biopsy using blue dye for early breast cancer staging: a single-centre experience in Addis Ababa, Ethiopia. East Cent Afr J Surg. 2024;29(1):16-22
- 14. Suga Y, Teklewold B, Ariaya A, Shimeles R, Jibril A. Feasibility of sentinel lymph node biopsy in a resource limited setting: an initial experience from Ethiopia. Ethiop J Health Sci. 2026;36(2):113-7.
- 15. Brand NR, Wasike R, Makhdomi K, et al. Sentinel lymph node biopsy pathology and 2-year postsurgical recurrence of breast cancer in Kenyan women. J Glob Oncol. 2018;4:1-7.
- 16. Yousef M, Roodt L, Masu A, Nel D, Malherbe F. Sentinel lymph node biopsy in a resource-limited setting: a retrospective comparison of sentinel lymph node biopsy before and after the introduction of Sentimag at an academic breast unit. S Afr J Surg. 2023;61(2):91-5.
- 17. Belkhodja A, Chiba Y, Zaabar L, Jaafar W, Malak M, Bouassida M, et al. Sentinel lymph node biopsy for breast cancer in North Africa: a retrospective analysis of feasibility, safety, and morbidity reduction in a real-world setting. Eur J Breast Health. 2026;22(1):61-5.
- 18. Seenu V, Suhani S, Srivastava A, Parshad R, Mathur S, Kumar R. Optimization of sentinel lymph node identification techniques in the Indian setting: a randomized clinical trial. Indian J Cancer. 2019;56(2):114-8.
- 19. Valiveru RC, Agarwal G, Agrawal V, Gambhir S, Mayilvaganan S, Chand G, et al. Low-cost fluorescein as an alternative to radio-colloid for sentinel lymph node biopsy—a prospective validation study in early breast cancer. World J Surg. 2020;44:3417-22.
- 20. Khadka S, Suresh J, Prem A, Mishra PR, Kataria K, Dhar A, et al. Sentinel node mapping in early breast cancer: a randomized comparison of fluorescein guided All India Institute of Medical Sciences, Anurag's technique with technetium-99m sulfur colloid plus methylene blue. Indian J Nucl Med. 2022;37(3):236-44.
- 21. Chavda J, Mishra A, Silodia A, Yadav SK, Sharma DB, Sharma D, et al. Validation sentinel lymph node biopsy study in cN0 axilla using low-cost dual dye technique: potential solution for resource poor settings. Breast Cancer Res Treat. 2022;193:105-10
- 22. Sethi RS, Kaur N, Patni S, Sharma P, Sharma A, Hussaini SS. Combined fluorescein and methylene blue dye for sentinel lymph node biopsy in patients of early carcinoma breast: a promising technique. Indian J Surg Oncol. 2024;15(4):891-900.
- 23. Gupta P, Agarwal VK, Varshney AK. Assessment of sensitivity of low-cost fluorescein as an alternative to radiocolloid for sentinel lymph node biopsy in breast carcinoma. Rep Pract Oncol Radiother. 2026;31(1):50-8.
- 24. Suhani, Kumar U, Seenu V, Sodhi J, Joshi M, Bhattacharjee HK, et al. Evaluation of dual dye technique for sentinel lymph node biopsy in breast cancer: two-arm open-label parallel design non-inferiority randomized controlled trial. World J Surg. 2023;47:2178-85.
- 25. Agrawal SK, Hashlamoun I, Karki B, Sharma A, Arun I, Ahmed R. Diagnostic performance of indocyanine green plus methylene blue versus radioisotope plus methylene blue dye method for sentinel lymph node biopsy in node-negative early breast cancer. JCO Glob Oncol. 2020;6:1225-31.
- 26. Somashekhar SP, Kumar CR, Ashwin KR, et al. Can low-cost indocyanine green fluorescence technique for sentinel lymph node biopsy replace dual dye (radio-colloid and blue dye) technique in early breast cancer: a prospective two-arm comparative study. Clin Breast Cancer. 2020;20(5).
- 27. Hidar S, Alimi A, Khlifi A, Chachia S, Kaabia O, Bouguizane S, et al. Indocyanine green fluorescence-guided sentinel node biopsy in breast cancer within a North African population: a retrospective study. Eur J Breast Health. 2021;17(4):352-5.
- 28. Sugie T, Ikeda T, Kawaguchi A, Shimizu A, Toi M. Sentinel lymph node biopsy using indocyanine green fluorescence in early-stage breast cancer: a meta-analysis. Int J Clin Oncol. 2017;22(1):11-7.
- 29. Mooghal M, Ali ZM, Saleem L, Yaqoob A, Ahmad F, Jamal A. Evaluating gentian violet as a low-cost alternative for sentinel lymph node biopsy in breast cancer: a single-center retrospective study. Asia Pac J Clin Oncol. 2026.
- 30. Park B, Han M, Park J, Kim T, Ryu H, Seo Y, et al. A photoacoustic finder fully integrated with a solid-state dye laser and transparent ultrasound transducer. Photoacoustics. 2021;23:100290.
- 31. Han M, Lee YJ, Ahn J, et al. A clinical feasibility study of a photoacoustic finder for sentinel lymph node biopsy in breast cancer patients: a prospective cross-sectional study. Photoacoustics. 2025;43:100716.
- 32. Yadav SK, Garg G, Baderiya D, et al. BRIDGEing the gap: impact of a short virtual course on delivering global-standard breast cancer care in low-resource settings. World J Surg. 2026;50(2):385-92.
- 33. Yadav SK, Nema M, Sharma DB, Agarwal P, Sharma D. Mastering low-cost sentinel lymph node biopsy using fluorescein sodium and methylene blue dye: evaluating its learning curve in breast cancer surgery. Indian J Surg Oncol. 2026;17(6):1435-9.
- 34. Bandaranayake V, Nellihela AP, Asanthi J, et al. Outcomes of methylene blue single-dye sentinel lymph node biopsy in early breast cancer: a retrospective cohort study from a resource-limited tertiary centre. Research Square [Preprint]. 2026.
- 35. Ratnagiri R, Srivastava MK, Uppin MS, et al. Performing sentinel lymph node biopsy without a hand-held gamma probe—overcoming hurdles through teamwork: an analysis of our learning curve over five years. World J Surg Oncol. 2025;23(1):285.
- 36. Buccimazza I. Implementing sentinel lymph node biopsy programs in developing countries: challenges and opportunities. World J Surg. 2011;35(6):1155-8.
- 37. Anderson BO, Yip CH, Smith RA, et al. Guideline implementation for breast healthcare in low-income and middle-income countries. Cancer. 2008;113(8 Suppl):2221-43.
- 38. Park KU, Somerfield MR, Anne N, Brackstone M, Conlin AK, Couto HL, et al. Sentinel lymph node biopsy in early-stage breast cancer: ASCO guideline update. J Clin Oncol. 2025;43(14):1720-41.
- 39. Giuliano AE, Ballman KV, McCall L, Beitsch PD, Brennan MB, Kelemen PR, et al. Effect of axillary dissection vs no axillary dissection on 10-year overall survival among women with invasive breast cancer and sentinel node metastasis: the ACOSOG Z0011 (Alliance) randomized clinical trial. JAMA. 2017;318(10):918-26.
- 40. Bartels SAL, Donker M, Poncet C, et al. Radiotherapy or surgery of the axilla after a positive sentinel node in breast cancer: 10-year results of the randomized controlled EORTC 10981-22023 AMAROS trial. J Clin Oncol. 2023;41(12):2159-65.
APPENDIX
Appendix I
Two gates separate team readiness from independent practice and require re-proctoring when performance deteriorates. The pathway is an author-proposed implementation framework rather than a validated credentialing guideline.
The South African bar represents the proportion of eligible patients receiving SLNB after Sentimag introduction, not an identification rate.
Appendix II
Reproducible search strategy
Search date: 24 August 2026. No start date was applied. Language was restricted to English during eligibility assessment.
PubMed
("Breast Neoplasms"[Mesh] OR "breast cancer"[tiab]) AND ("sentinel lymph node biopsy"[tiab] OR "sentinel node biopsy"[tiab] OR "sentinel lymph node mapping"[tiab]) AND ("methylene blue"[tiab] OR fluorescein[tiab] OR "gentian violet"[tiab] OR "indocyanine green"[tiab] OR ICG[tiab] OR photoacoustic[tiab] OR "low resource"[tiab] OR "resource limited"[tiab] OR "resource constrained"[tiab] OR "developing country"[tiab] OR Africa[tiab] OR Ethiopia[tiab] OR Nigeria[tiab] OR Kenya[tiab] OR Ghana[tiab] OR Egypt[tiab] OR Morocco[tiab] OR Tunisia[tiab] OR India[tiab] OR Pakistan[tiab] OR Bangladesh[tiab] OR "Sri Lanka"[tiab] OR Nepal[tiab] OR Indonesia[tiab] OR implementation[tiab] OR feasibility[tiab] OR training[tiab] OR "learning curve"[tiab] OR cost[tiab] OR barriers[tiab] OR infrastructure[tiab])
Records returned: 1,193.
Europe PMC
TITLE_ABS:"breast cancer" AND (TITLE_ABS:"sentinel lymph node biopsy" OR TITLE_ABS:"sentinel node biopsy" OR TITLE_ABS:"sentinel lymph node mapping") AND (TITLE_ABS:"methylene blue" OR TITLE_ABS:fluorescein OR TITLE_ABS:"gentian violet" OR TITLE_ABS:"indocyanine green" OR TITLE_ABS:ICG OR TITLE_ABS:photoacoustic OR TITLE_ABS:"low resource" OR TITLE_ABS:"resource limited" OR TITLE_ABS:"resource constrained" OR TITLE_ABS:implementation OR TITLE_ABS:feasibility OR TITLE_ABS:training OR TITLE_ABS:"learning curve" OR TITLE_ABS:cost OR TITLE_ABS:barriers OR TITLE_ABS:infrastructure) AND FIRST_PDATE:[1900-01-01 TO 2026-08-24]
Records returned: 1,109.
Other methods
Reference lists of included reports and relevant journal websites were searched for regional studies and implementation guidance. Five reports entered full text assessment through these methods.
Deduplication and screening
The platform search counts sum to 2,302, while 2,301 records were present in the merged retrievable exports used for deduplication and screening. Deduplication by DOI or normalised title removed 1,049 records, leaving 1,252 unique records for title and abstract screening. Of these, 1,070 were excluded at title/abstract screening and 182 database reports were sought for retrieval. Seven were not retrieved, leaving 175 database reports assessed in full text. Five additional reports identified through other methods entered full-text assessment, giving 180 full-text reports assessed. A total of 144 full-text reports were excluded (wrong context, 61; wrong intervention, 38; insufficient data, 20; preclinical, 12; other report type, 8; duplicate report, 5), and 36 evidence sources were included.
Appendix III
PRISMA-ScR checklist.
The checklist follows the 20 essential and two optional PRISMA-ScR reporting items. Page locations refer to this revised blinded manuscript.