International Journal of Research in Orthopaedics

Mohammed MA et al. Int J Res Orthop. 2024 Jan;10(1):50-56

http://www.ijoro.org

An observational retrospective study on safety and functional outcomes of arthroscopic anterior cruciate ligament reconstruction using Sironix suture button and interference screw

Murtuza Ahmed Mohammed1, Apurve Parameswaran2, Vinay Kishore Ponnala2, Krishna Kiran Eachempati2, Sunil Apsingi2, Ashok Kumar Moharana3, Sachin Angrish3, Deepak T. S.3*


1Department of Orthopaedic Surgery, Burjeel Farha Hospital LLC, Al Ain, Abu Dhabi, United Arab Emirates

2Department of Orthopaedic Surgery, Medicover Hospitals, Hi-tech City, Hyderabad, Telangana, India

3Clinical Affairs, Healthium Medtech Limited, Bangalore, Karnataka, India

Received: 05 December 2023

Accepted: 20 December 2023

*Correspondence:

Dr. Deepak T. S.,

E-mail: deepak.ts@healthiummedtech.com

Copyright: © the author(s), publisher and licensee Medip Academy. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

ABSTRACT

Background: Anterior cruciate ligament (ACL) injury is a persistent orthopaedic condition that affects a wide spectrum of people. ACL reconstruction (ACL-R) stands out as the primary treatment option. Graft fixation with suture buttons and interference screws has proven to be a highly successful and reliable method for ACL-R. In this context, our research aims to assess the safety and functional outcomes of patients who underwent arthroscopic ACL-R using the Sironix suture button and interference screw.

Methods: This was a retrospective observational study. Patients who underwent arthroscopic ACL-R using Sironix suture button and interference screw (January 2018-March 2022) were included in the study. Functional outcomes of patients were evaluated using the international knee documentation committee (IKDC) assessment, the Tegner activity scale (TAS), the Lysholm knee scoring scale, the modified knee injury and osteoarthritis outcome score (KOOS) quality of life subscale, and the single assessment numerical evaluation (SANE) score. Adverse events, if any, were recorded.

Results: All patients achieved excellent outcome measures for IKDC, Tegner, Lysholm, KOOS, and SANE scores. The mean (SD) IKDC score was 88.76 (7.16), Tegner activity score was 5.9 (1.13), while the Lysholm score was 96.9 (6.56). The overall KOOS score was 93.7 (7.52), and the overall SANE score for the affected joint was 94.5 (7.22).

Conclusions: Arthroscopic ACL-R using Sironix implants (Helysis titanium interference screw, Helysis PLDLA+β-TCP interference screw, Infiloop fixed loop UHMWPE suture titanium button, Proloop adjustable loop UHMWPE suture Titanium button, and Titanium suture disc) demonstrated safety and good functional outcomes.

Keywords: ACL injury, ACL-R, IKDC, Interference screw, Sironix suture button

INTRODUCTION

Anterior cruciate ligament (ACL) injuries are the most common type of ligament injuries, and result in knee instability. The ACL serves as the primary internal stabilizing ligament of the knee.1,2 The estimated incidence of ACL tears in the general population is approximately 0.24-0.34 per 1,000 people per year.3 ACL injuries most frequently affect people between the ages of 20 and 24.4 The most successful and recommended procedure for restoring knee stability and improving overall knee function is ACL-R.5,6

Arthroscopic ACL-R is widely acknowledged as a highly effective procedure that consistently delivers favorable outcomes for most of the patients. It is recognized as the preferred treatment for individuals who suffer from functional instability due to an ACL injury.7 ACL-R has success rates ranging from 75% to 97%. This surgical intervention can deliver exceptional results in terms of graft stability, enabling patients to return to athletic activities and mitigating functional knee instability.8

Although ACL-R has demonstrated success in restoring knee stability, recent research has revealed a notable occurrence of revision surgery, with revision rates ranging from 4.1% to 13%.9 ACL-R has predominantly centered around individual practice patterns, selection of graft type, surgical approach, and other technical aspects of the procedure.10 Selecting appropriate graft tissue is of paramount importance in this context. Graft options include autografts, allografts, and synthetic ligaments.11 Hamstring and patellar tendon autografts have both proven to be successful options for graft fixation in ACL-R, traditionally secured with metallic interference screws made of materials like steel or titanium.12

In recent decades, substantial progress has occurred, leading to significant changes in surgical approaches.13 Moreover, in recent times, there has been a shift towards the use of interference screws made of bio-absorbable materials, such as poly-L-lactic acid. Bio-absorbable materials have gained popularity as they ensure appropriate graft-to-bone fixation.14,15 Sutures and screws are the most frequently recommended fixation devices for ACL-R. There has been a recent surge in the popularity of ultra-high molecular weight polyethylene (UHMWPE) sutures as fixation devices, offering improved knee stability.16

Suture button-based femoral cortical suspensory fixation can facilitate fast and secure graft fixation following ACL-R.17 Metallic interference screws have shown favorable clinical results with minimal complication rates.18 Interference screws made of titanium provide adequate fixation strength and facilitate rapid integration with the surrounding bone.19 The limited literature evaluating functional outcomes following ACL-R, and the wide variations in their findings, underscore the need for more research on the subject. The purpose of the current research was to assess the safety and functional outcomes following ACL-R using the Sironix suture button and interference screw.

METHODS

Following institutional ethics committee approval, a retrospective observational study was undertaken. Patients aged 18 to 60 years, who underwent arthroscopic ACL-R between January 2018 and March 2022 at Medicover Hospitals in Hyderabad, India using the Sironix suture button and interference screw, at a high-volume tertiary care center, were recruited for the study. Patients who did not respond to calls after three attempts or were not interested in participating in the study, and patients with traumatic injury to the same knee post ACL-R were excluded from the study. Informed consent was obtained from all patients. All patients who met the inclusion criteria were asked to complete outcome questionnaires to assess functional outcomes.

Data collection and outcomes

Comprehensive pre-operative data were collected for each patient, including demographic details [age, height, weight, body mass index (BMI), and gender], injury related information (type of injury, cause, and concurrent knee pathology), and clinical evaluation findings (from knee examination). The primary endpoint of the study was knee function following ACL-R, assessed using the IKDC assessment form. The secondary endpoints assessed were level of activity post ACL-R using the TAS and Lysholm score, the quality-of-life post ACL-R using modified KOOS quality of life (QOL) subscale, and SANE score on scale of 0-100. Adverse events, if any, were documented.

Figure 1: Study implants.
Figure 1: Study implants.

Choice of graft and implants

Semitendinosus and gracilis autograft were used in all patients. Surgery was performed using Sironix implants for graft fixation (Figure 1). Femoral side fixation was performed using the proloop adjustable loop UHMWPE suture titanium button (Sironix Division, Healthium Medtech Limited, India) or the infiloop fixed loop UHMWPE suture titanium button (Sironix Division, Healthium Medtech Limited, India), both of which were composed of two components: a variable suture loop and a metal fixation device (button). The suture portion of the fixation device is made of UHMWPE, and the fixation device (button) is made of titanium alloy. In two patients, the Helysis PLDLA + β-TCP interference screw was used for femoral fixation. The tibial fixation was performed using the Helysis titanium interference screw (Sironix Division, Healthium Medtech Limited, India) or the Helysis PLDLA + β-TCP interference screw (Sironix Division, Healthium Medtech Limited, India), which is made of PLDLA-βTCP [poly (L-co-DL lactic acid) + Beta Tricalcium phosphate]. In addition to the above implants, for posterior cruciate ligament (PCL) injury repair, Titanium suture disc was used (Sironix Division, Healthium Medtech Limited, India).

Statistical analysis

Categorical variables were represented as percentages, while numerical variables were expressed using means and standard deviation. Statistical analysis was performed using SAS software (version 9.4).

RESULTS

Demographics and other baseline characteristics

A total of 32 patients who fulfilled the eligibility criteria were available for follow-up and were included in the study. Their mean (SD) age was 34.3 (8.37) years. Of these, 24 (75%) were male and 8 (25%) were female. Femoral fixation was performed using Proloop adjustable loop UHMWPE suture titanium button for three patients, Infiloop fixed loop UHMWPE suture titanium button for 27 patients and Helysis PLDLA+β-TCP interference screw for two patients. The tibial fixation was performed using Helysis PLDLA+β-TCP interference screw for 19 patients, and Helysis titanium interference screw for 13 patients. Details of demographic characteristics, ACL injury and ACLR surgery are provided in Table 1.

Number of devices implanted

A total of 69 devices were implanted in 32 patients, comprising 14 Helysis titanium interference screws, 22 Helysis PLDLA + β-TCP interference screws, 28 IGnfiloop fixed loop UHMWPE suture titanium buttons, 3 proloop Adjustable loop UHMWPE suture titanium buttons and 2 titanium suture disc implants (Figure 2).

Table 1: Demographic characteristics of the study population, and details pertaining to ACL injury and ACL-R.
Table reproduced from source PDF page 3, part 1 of 2
Table reproduced from source PDF page 4, part 2 of 2
Figure 2: Implanted devices.
Figure 2: Implanted devices.

Assessment of functional outcomes

Primary functional outcome

Evaluation of IKDC assessment score: The overall mean (SD) value of the IKDC assessment score of 32 patients was 88.76 (7.16) (Table 2).

IKDC assessment by device: Mean (SD) IKDC assessment scores, among patients who underwent ACL-R using Helysis PLDLA+β-TCP interference screw, Helysis titanium interference screw, Infiloop fixed loop UHMWPE suture titanium button, proloop adjustable loop UHMWPE suture titanium button, and titanium suture disc implants 90.4 (3.54), 86.0 (9.77), 88.9 (7.49), 91.6 (3.69), and 90.8 (4.88), respectively (Figure 3).

Figure 3: Analysis of IKDC assessment by device.
Figure 3: Analysis of IKDC assessment by device.

Secondary outcomes

Assessment of TAS and Lysholm score: The overall mean (SD) value of the total TAS was 5.9 (1.13). The overall mean (SD) value of the total Lysholm score was 96.9 (6.56) (Table 3).

Assessment of KOOS and SANE scores: The overall mean (SD) value of the KOOS score (QOL) was 93.7 (7.52). The overall mean (SD) value of the SANE score for the affected joint was 94.5 (7.22) (Table 4).

Adverse events

Out of the 32 patients included in the study, none reported any adverse events, and there were no instances where patient participation in the study had to be discontinued.

Table 2: Summary and analysis of IKDC assessment by duration following surgery.
Table reproduced from source PDF page 4
Table 3: Summary of TAS and Lysholm score.
Table reproduced from source PDF page 4
Table 4: Summary and analysis of KOOS score and SANE score by duration.
Table reproduced from source PDF page 5

DISCUSSION

Arthroscopic ACL-R continues to be the preferred treatment for knees with ACL deficiency, as most non-surgical approaches have yielded outcomes that are deemed functionally unacceptable.20

The primary goal of ACL-R is to restore stability and function to the knee joint after an ACL tear.21

Over the follow-up of two years, both in-clinic and via telephonic follow-ups, the study has diligently employed the primary and secondary endpoints to measure the outcomes, as outlined by the IKDC score, Tegner scale (TAS), Lysholm score, KOOS with a keen emphasis on the quality-of-life sub-scale, SANE, and any adverse events.

These measures have been utilized to gauge the effectiveness and safety of the Sironix suture button and interference screw.

In a study conducted by Shervegar et al following ACL-R surgery, a mean (SD) IKDC subjective score of 75.6 (17.36) was observed.20Another study by Ra et al reported a mean (SD) IKDC score of 89.8 (9.9) for a 12-month follow-up.22 In contrast, the current study findings indicate superior results with a mean (SD) IKDC score of 92.82 (1.45).

Cheng-Yao et al found that the mean Lysholm score at one-year follow-up was 82.4 (7.8), while the score at two years’ follow-up was 93.1 (8.5).23 In contrast, the results of the present study demonstrate a deviation from these earlier findings. It was found that the mean (SD) Lysholm scores at both the one-year and two-year follow-ups were higher, at 99.5 (0.58) and 96.2 (7.41), respectively.

According to the research conducted by Muller et al the mean (SD) KOOS score was 77.6 (19.7) after more than two years of follow-up.24 The KOOS score for the same follow-up period was much higher in the current study's findings, with a mean (SD) score of 92.8 (8.19), demonstrating a substantial difference.

In a study conducted by Chen et al the mean (SD) TAS score for patients who underwent single-bundle ACL-R at more than two years of follow-up was 6.59 (0.51).25 Comparable results were found in the current study, where the mean (SD) TAS score was 6.0 (1.25).

Douoguih et al conducted a retrospective study on patients who underwent ACL repair with suture augmentation to evaluate outcomes and patient satisfaction and demonstrated the mean (SD) SANE score was 83.0 (12.9).26 According to the current study, the mean (SD) SANE score was 94.5 (7.22), which was highly significant compared to the early findings.

Strengths and limitations

This study has a few limitations that should be acknowledged. Firstly, given its retrospective nature, there is a need for more prospective research, including randomized controlled trials, to strengthen the quality of the evidence. Secondly, there was a relatively small sample size. However, it is worth noting that the long-term follow-up data collected in a real-world setting does contribute valuable insights. Additionally, it is important to highlight that the results of this study have shown correlation with the existing literature in terms of the IKDC score, SANE score, Lysholm score, TAS, and KOOS quality of life score, which serves to validate the findings of the current study.

CONCLUSION

The study results demonstrate a significant functional status after ACL-R as evidenced by the IKDC score, SANE score, Lysholm score, TAS, and KOOS QOL score. Therefore, the utilization of the Sironix suture button (Infiloop fixed loop UHMWPE suture titanium button and Proloop adjustable loop UHMWPE suture titanium button) and interference screw (Helysis titanium interference screw and Helysis PLDLA + β-TCP interference screw) appears to be a safe and viable option while performing arthroscopic ACL-R.

ACKNOWLEDGEMENTS

Authors would like to thank Techsol life sciences for providing medical writing assistance for this manuscript..

Funding: Funding sources by Healthium Medtech Limited, Bangalore, India

Conflict of interest: Sunil Apsingi is a consultant to Healthium Medtech Limited. Ashok Kumar Moharana, Sachin Angrish, and Deepak T. S are full time employees of Healthium Medtech Limited. Other Authors declares no conflict of interest.

Ethical approval: The study was approved by the Institutional Ethics Committee

REFERENCES

  1. 1. Diermeier T, Rothrauff BB, Engebretsen L, Lynch AD, Ayeni OR, Paterno MV, Xerogeanes JW et al. Panther Symposium ACL Treatment Consensus Group. Treatment after anterior cruciate ligament injury: Panther Symposium ACL Treatment Consensus Group. Knee Surg Sports TraumatolArthrosc. 2020;28(8):2390-402.
  2. 2. Yoo H, Marappa-Ganeshan R. Anatomy, Bony Pelvis and Lower Limb, Knee Anterior Cruciate Ligament. In: StatPearls. Treasure Island (FL): StatPearls Publishing; 2023.
  3. 3. Sharma P, Baghel A, Keshav K, Kumar A, Singh A, Singh AB. Functional Outcomes of Anterior Cruciate Ligament Reconstruction Using Titanium Adjustable Loop Button and Poly-L-co-DL-Lactic Acid-Beta Tricalcium Phosphate (PLDLA-bTCP) Interference Screws: A Single-Center, Retrospective, Observational Study. Cureus. 2023;15(2):e34542.
  4. 4. Mlv SK, Mahmood A, Vatsya P, Garika SS, Mittal R, Nagar M. Demographic characteristics of patients who underwent anterior cruciate ligament reconstruction at a tertiary care hospital in India. World J Clin Cases. 2023;11(15):3464-70.
  5. 5. Krause M, Freudenthaler F, Frosch KH, Achtnich A, Petersen W, Akoto R. Operative Versus Conservative Treatment of Anterior Cruciate Ligament Rupture. DtschArztebl Int. 2018;115(51-52):855-62.
  6. 6. Chechik O, Amar E, Khashan M, Lador R, Eyal G, Gold A. An international survey on anterior cruciate ligament reconstruction practices. Int Orthop. 2013;37:201-6.
  7. 7. Rodriguez K, Soni M, Joshi PK, Patel SC, Shreya D, Zamora DI, Patel GS et al. Anterior Cruciate Ligament Injury: Conservative Versus Surgical Treatment. Cureus. 2021;13(12):e20206.
  8. 8. Wilde J, Bedi A, Altchek DW. Revision anterior cruciate ligament reconstruction. Sports Heal. 2014;6(6):504-18.
  9. 9. Liechti DJ, Chahla J, Chase S, Mitchell JJ, Sette E, Menge TJ, LaPrade RF. “Outcomes and Risk Factors of Rerevision Anterior Cruciate Ligament Reconstruction: A Systematic Review.” Arthroscopy. 2016;32(10):2151-9.
  10. 10. Longo UG, Nagai K, Salvatore G, Cella E, Candela V, Cappelli F, Ciccozzi M et al. Epidemiology of Anterior Cruciate Ligament Reconstruction Surgery in Italy: A 15-Year Nationwide Registry Study. J Clin Med. 2021;10(2):223.
  11. 11. Sun J, Wei XC, Li L, Cao XM, Li K, Guo L, Lu JG et al. “Autografts vs Synthetics for Cruciate Ligament Reconstruction: A Systematic Review and Meta-Analysis.” Orthop Surg. 2020;12(2):378-87.
  12. 12. Buerba RA, Boden SA, Lesniak B. Graft Selection in Contemporary Anterior Cruciate Ligament Reconstruction. J Am AcadOrthopSurg Glob Res Rev. 2021;5(10):e21.00230.
  13. 13. Vaishya R, Agarwal A, Ingole S, Vijay V. Current Trends in Anterior Cruciate Ligament Reconstruction: A Review. Cureus. 2015;7(11): e378.
  14. 14. Lee DW, Lee JW, Kim SB, Park JH, Chung KS, Ha JK, Kim JG et al. Comparison of Poly-L-Lactic Acid and Poly-L-Lactic Acid/Hydroxyapatite Bioabsorbable Screws for Tibial Fixation in ACL Reconstruction: Clinical and Magnetic Resonance Imaging Results. Clin Orthop Surg. 2017;9(3):270-9.
  15. 15. Pereira H, Correlo VM, Silva-Correia J, Oliveira JM, Reis RL, Espregueira-Mendes J. Migration of "bioabsorbable" screws in ACL repair. How much do we know? A systematic review. Knee Surg Sports Traumatol Artosc. 2013;21(4):986-94.
  16. 16. Mortazavi SMJ, Hasani SS, Vosoughi F, Rezaei Dogahe R, Besharaty S. Arthroscopic Fixation of Anterior Cruciate Ligament Avulsion Fracture Using FiberWire Suture With Suture Disc. Arthrosc Tech. 2021;10(7):e1709-15.
  17. 17. Ohnishi Y, Chang A, Utsunomiya H, Suzuki H, Nakamura E, Sakai A, Uchida S. “Arthroscopic Technique to Reduce Suture Button Migration During Anterior Cruciate Ligament Reconstruction Procedure.” Arthroscopy Techn. 2017;6(5):e1927-31.
  18. 18. Sundaraj K, Salmon LJ, Heath EL, Winalski CS, Colak C, Vasanji A, Roe JP et al. Bioabsorbable Versus Titanium Screws in Anterior Cruciate Ligament Reconstruction Using Hamstring Autograft: A Prospective, Randomized Controlled Trial With 13-Year Follow-up. Am J Sports Med. 2020;48(6):1316-26.
  19. 19. Papalia R, Vasta S, D'Adamio S, Giacalone A, Maffulli N, Denaro V. Metallic or bioabsorbable interference screw for graft fixation in anterior cruciate ligament (ACL) reconstruction? Br Med Bull. 2014;109:19-29.
  20. 20. Shervegar S, Nagaraj P, Grover A, Dj NG, Ravoof A. Functional Outcome Following Arthroscopic ACL Reconstruction with Rigid Fix: A Retrospective Observational Study. Arch Bone Jt Surg. 2015;3(4):264-8.
  21. 21. Chitten JJ, Arora M. A Prospective Observational Study on Short-Term Functional Outcome of Arthroscopic Anterior Cruciate Ligament Repair of Proximal Tears Using Knotless Single Suture Anchor Technique. Indian J Orthop. 2021;56(3):437-44.
  22. 22. Ra HJ, Kim HS, Choi JY, Ha JK, Kim JY, Kim JG. Comparison of the ceiling effect in the Lysholm score and the IKDC subjective score for assessing functional outcome after ACL reconstruction. Knee. 2014;21(5):906-10.
  23. 23. Cheng-Yao L, Chuan-Dong L, Liang W, Shan R, Fu-Bin Y, Jin-Guang, Jiang-Xiong M. Function scores of different surgeries in the treatment of knee osteoarthritis: A prisma-compliant systematic review and network-meta-analysis. Medicine. 2018;97(21):e10828.
  24. 24. Muller B, Yabroudi MA, Lynch A, Lai CL, Van DCN, Fu FH, Irrgang JJ. “Defining Thresholds for the Patient Acceptable Symptom State for the IKDC Subjective Knee Form and KOOS for Patients Who Underwent ACL Reconstruction.” The American journal of sports med. 2016;44(11):2820-6.
  25. 25. Chen K, Zhu W, Zheng Y, Zhang F, Ouyang K, Peng L, Liu H et al. A retrospective study to compare the clinical effects of individualized anatomic single-and double-bundle anterior cruciate ligament reconstruction surgery. Sci Rep. 2020;10(1):14712.
  26. 26. Douoguih WA, Zade RT, Bodendorfer BM, Siddiqui Y, Lincoln AE. Anterior Cruciate Ligament Repair with Suture Augmentation for Proximal Avulsion Injuries. Arthrosc Sports Med Rehabil. 2020;2(5):e475-80.