Case ReportInternational Journal of Contemporary Pediatrics

Publication:
Use of magnet powered bronchoscopy forceps in the removal of bronchial metallic foreign body in an adolescent girl

Int J Contemp Pediatr. 2026;13(1):92-94.DOI10.18203/2349-3291.ijcp20254192

Thumbnail Image
View on the journal's website(opens in a new tab)

Abstract

Aspiration of foreign body is defined as an entry of an object into the respiratory tract. The mainstay of treatment for removal of the foreign body is bronchoscopy. Here, we report an eleven-year-old girl who presented with accidental aspiration of right bronchial metallic foreign body, which was difficult to remove by conventional bronchoscopy forceps but ultimately removed by magnet powered forceps.

Keywords

Affiliations

  1. Government Medical College, Ratnagiri, Maharashtra, India
  2. Department of Pediatrics, D. Y. Patil Medical College, D. Y. Patil Education Society (Deemed to be University), Kolhapur, Maharashtra, India
  3. Om Sai Childrens Hospital and Pulmonology Clinic, Kolhapur, Maharashtra, India

Full item record