Original Research ArticleInternational Surgery Journal
Publication: A comparative study between direct safety trocar insertion versus veress needle technique for creating pneumoperitoneum in laparoscopic surgeries
Int Surg J. 2021;8(10):3103-3108.DOI10.18203/2349-2902.isj20214003
Abstract
Background There are two methods of trocar insertion in laparoscopic surgeries one is direct insertion and second is Veress needle insertion. In this study we compared these two methods.
Methods In this study we divided 50 patients equally into two group group A for in group A patients, direct trocar insertion technique was used for creation of pneumoperitoneum whereas amongst patients of group B, pneumoperitoneum was created using Veress needle insertion technique.
Results The incidence of visceral injuries, vascular injuries and other post-operative complications were similar in both the groups. The present study observed no significant difference in failure rates between two methods.
Conclusions Both the techniques i.e.; Direct trocar insertion (DTI) and Veress needle technique are equally effective, safe and feasible for creation of pneumoperitoneum during laparoscopic procedure.
Keywords
Affiliations
- Department Surgery, PCMS and RC, Bhopal, Madhya Pradesh, India