International Journal of Contemporary Pediatrics

Das A et al. Int J Contemp Pediatr. 2024 Nov;11(11):1628-1636

http://www.ijpediatrics.com

pISSN 2349-3283 | eISSN 2349-3291

Assessment of left ventricular function in patient after ventricular septal defect closure using echocardiography

Aditi Das1*, Edwin Dias2, Touseef Ul Ayoub3, Neeraj Awasthy3, Devender Sangwan3, Vaishali Jain3


1Department of Allied Health sciences, Srinivas University, Mangalore, Karnataka, India

2Department of Paediatric, Srinivas Hospital, Mangalore, Karnataka, India

3Department of Paediatric Cardiology, Fortis Escort Heart Institute, New Delhi, India

Received: 29 August 2024

Accepted: 02 October 2024

*Correspondence:

Dr. Aditi Das,

E-mail: aditidas2306@gmail.com

Copyright: © the author(s), publisher and licensee Medip Academy. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

ABSTRACT

This systematic literature review assessed left ventricular function in patients after ventricular septal defect (VSD) closure, with a focus on echocardiographic evaluations. Echocardiography plays a vital role in monitoring cardiac function following VSD closure, whether performed through surgery or device catheter treatment, and is essential for guiding patient management. A thorough search was conducted across multiple databases, including PubMed, Google Scholar, and Scopus, resulting in the identification of 32 records. Of these, 7 studies met the inclusion criteria, encompassing sample sizes ranging from 7 to 188 patients. The selected studies focused on evaluating left ventricular function using echocardiographic techniques after VSD closure. The majority of patients demonstrated normal left ventricular function following VSD closure. However, a subset experienced a temporary decline in left ventricular ejection fraction (LVEF) and global longitudinal strain (GLS) immediately post-procedure. These impairments generally improved during follow-up, indicating a recovery of left ventricular function over time. Residual lesions were uncommon, with only a small number of patients exhibiting minor residual shunts. VSD closure, whether through surgery or device catheter treatment, is typically associated with significant improvements in left ventricular function. Although some patients may experience a transient decline in LVEF and GLS, recovery is common during follow-up. These findings highlight the critical role of echocardiography in ongoing assessment and monitoring, which is crucial for optimal long-term management and follow-up of patients after VSD closure.

Keywords: Ventricular septal defect, Left ventricular function, VSD closure, Echocardiography

INTRODUCTION

Congenital heart defects, affecting about 1% of new-borne, are the most common fatal birth abnormalities and often require early intervention due to their significant impact on infant health.1,2 The assessment of left ventricular function is a critical component in the management of patients who have undergone surgical closure of a ventricular septal defect (VSD).1 VSD, a common congenital heart defect, involves an abnormal opening in the septum that divides the left and right ventricles, allowing blood to pass from the left to the right ventricle, which can lead to heart failure, pulmonary hypertension, and other serious complications if left untreated.3 Ventricular septal defect (VSD) is the most prevalent cardiac anomaly, representing 25% of all congenital heart diseases.4

Surgical closure of the defect aims to restore normal hemodynamics and improve patient outcomes.5 Echocardiography plays a pivotal role in the perioperative and postoperative evaluation of patients with VSD. This non-invasive imaging modality provides comprehensive information about cardiac structure and function, enabling clinicians to assess the success of the surgical repair and to monitor for potential complications such as residual shunts, ventricular dysfunction, or arrhythmias.6

The evaluation of left ventricular function in these patients is particularly important, as it can influence clinical decisions and long-term management strategies.7 Several echocardiographic parameters, including ejection fraction, fractional shortening, and myocardial strain, are commonly used to assess left ventricular performance.8 Advanced echocardiographic techniques, such as three-dimensional echocardiography and speckle-tracking echocardiography, offer enhanced accuracy and detailed assessment of myocardial mechanics.9

Despite the advancements in surgical techniques and postoperative care, some patients continue to experience impaired left ventricular function after VSD closure.10 This underscores the need for ongoing research to optimize surgical outcomes and to develop effective monitoring strategies.11

One major limitation is the unclear significance of near-normal LVEF values. When LVEF exceeds 40-45%, it may not reliably correspond with symptoms, predict outcomes, or guide treatment, even though substantial systolic dysfunction could still be present when assessed with more sensitive techniques.12,13 This systematic literature review aims to synthesize the current evidence on the assessment of left ventricular function in patients following VSD closure using echocardiography. By critically evaluating the available studies, we seek to provide insights into the most reliable echocardiographic parameters, identify gaps in the existing knowledge, and propose areas for future research.

Understanding the nuances of left ventricular function assessment in this patient population is crucial for improving clinical outcomes and enhancing the quality of life for individuals with congenital heart defects.

METHODS

Study selection

This systematic review and meta-analysis were conducted in accordance with the preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines.14 A comprehensive search strategy was implemented to identify relevant studies assessing left ventricular function in patients post-ventricular septal defect (VSD) closure using echocardiography.

The search was conducted across multiple databases, including PubMed, Google Scholar, Scopus, and Web of Science, employing a combination of keywords and medical subject headings (MeSH) terms relevant to VSD, left ventricular function, and echocardiography. A total of 32 records were retrieved from the databases, with an additional 17 records identified through citation searching. After removing duplicate records (n=5) and those deemed ineligible by automation tools (n=2), 22 records remained for screening. Following the screening of titles and abstracts, 4 records were excluded due to irrelevance. Full texts were sought for the remaining 18 records, of which 3 could not be retrieved. After assessing the full texts of 15 reports, 7 studies were included in the review, along with 3 additional studies from citation searching that met the inclusion criteria. Studies were selected based on predefined inclusion criteria, focusing on observational studies that reported echocardiographic outcomes in patients post-VSD closure.

Data extraction

Data extraction was performed using a standardized form designed to capture essential study characteristics and outcomes. Extracted data included study information (author, year, country), patient demographics (age, gender), VSD specifics (type, size, location), echocardiographic parameters (left ventricular ejection fraction, fractional shortening, global longitudinal strain), follow-up duration, and other relevant clinical outcomes. Efforts were made to contact study authors for any missing or unclear data. Any discrepancies in data extraction were resolved through discussion between the reviewers.

Methodological quality and risk of bias assessment

The risk of bias in the included observational studies was assessed using the newcastle-ottawa scale (NOS). The NOS evaluates studies across three broad domains: selection of study groups, comparability of groups, and ascertainment of exposure or outcome of interest. Each study was awarded up to nine stars, with higher scores indicating a lower risk of bias. Studies were categorized as having low, moderate, or high risk of bias based on their NOS scores. Disagreements between reviewers were resolved through consensus or consultation with a third reviewer when necessary.

Statistical analysis

R version 4.4.1 was used for the statistical analysis. The sample mean and standard deviation were calculated in accordance with the Cochrane Handbook for Systematic Reviews of Interventions for studies that provided the median and the first and third quartiles. The primary outcome of interest was the assessment of left ventricular function following VSD closure, as measured by echocardiography.

Due to heterogeneity among study designs and outcome measures, a narrative synthesis was primarily employed. Where applicable, a meta-analysis was conducted using Review Manager (RevMan 5.4). Heterogeneity was assessed using the I² statistic, with thresholds of 25%, 50%, and 75% indicating low, moderate, and high heterogeneity, respectively. A random-effects model was applied when substantial heterogeneity was detected. The Chi-square test with Yates' continuity correction was used to evaluate common diagnoses, and sensitivity analyses were performed to explore the robustness of the findings. Publication bias was assessed using funnel plots and Egger’s test.

Figure 1: The studies for meta-analysis.15
Figure 1: The studies for meta-analysis.15

RESULTS

The systematic review included studies examining left ventricular function in patients after ventricular septal defect (VSD) closure, using various echocardiographic parameters. Table 1 provides an overview of the included research.

Demographics and study characteristics

A total of 10 studies were included in the review, with publication years ranging from 1994 to 2023. The sample sizes varied from 7 to 188 patients, with ages ranging from 0.3 years to over 15 years. The types of VSD studied included perimembranous, muscular, doubly committed, inlet, outlet, sabaortic, and apical muscular VSDs. The majority of studies focused on perimembranous VSD, while other types were less frequently reported.

Echocardiographic findings

Post-VSD closure, several studies reported significant changes in left ventricular function.

Ventricular function

Most studies reported normal left ventricular function in the majority of patients post-VSD closure. However, some studies documented a decrease in LVEF (left ventricular ejection fraction) and GLS (global longitudinal strain) immediately following the procedure, with gradual recovery in subsequent follow-ups.

For instance, Banpurkar et al noted that only one patient exhibited left ventricular dysfunction with an LVEF of 47%, GLS of-17.4%, and FS (fractional shortening) of −20.5%.16 In contrast, Elgayar et al. (2023) observed a temporary decrease in LVEF and GLS one-week post-closure, with improvement by the 6-week follow-up.17

Residual lesions and pulmonary arterial hypertension

Banpurkar et al reported that 92.1% of patients had no residual VSD post-surgery, and no cases of pulmonary arterial hypertension were observed.16 In contrast, Meijboom et al, noted that 8% of patients had small residual VSDs during long-term follow-up.22

Fractional shortening and regional strain

Several studies assessed fractional shortening and regional strain. Banpurkar et al found a mean FS of 32.0% and a basal anteroseptal segment strain of −21.4% .16 Regional variations in strain were noted, with a significant decrease in strain values in the basal anteroseptal segment compared to other segments.

Comparative outcomes

In studies comparing surgical and transcatheter VSD closure, it was observed that transcatheter methods generally resulted in better preservation of left ventricular function. Pawelec-Wojtalik et al reported higher ejection fraction and reduced mitral regurgitation in the Membr VSDO (occluder) group compared to the surgical group.23

Long-term outcomes

Long-term follow-up studies indicated that left ventricular function remained stable in the majority of patients. Roos-Hesselink et al and Menting et al, observed that the majority of patients had normal left ventricular dimensions and good functional status years after surgery, with only a small percentage showing impaired systolic function or residual shunting.24,25

Main findings

The findings of this review suggest that VSD closure, whether surgical or via transcatheter methods, generally leads to significant improvements in left ventricular function. While some patients may experience a temporary decline in function immediately after the procedure, most recover within a few weeks.

The type of VSD and the method of closure did not significantly influence the long-term outcomes, with most patients showing good recovery and stable function during follow-up.

However, regional variations in strain and the potential for residual shunting highlight the need for careful monitoring and follow-up in these patients.

Table 1: Over view of included studies.
Table reproduced from source PDF page 4, part 1 of 4
Table reproduced from source PDF page 5, part 2 of 4
Table reproduced from source PDF page 6, part 3 of 4
Table reproduced from source PDF page 7, part 4 of 4
Table reproduced from source PDF page 6

DISCUSSION

This systematic review examines the impact of ventricular septal defect (VSD) closure on left ventricular (LV) function, focusing on echocardiographic outcomes across various studies with differing methodologies and patient demographics.

Left ventricular function after VSD closure

Most studies report that LV function typically normalizes following VSD closure. Key echocardiographic parameters such as left ventricular ejection fraction (LVEF) and global longitudinal strain (GLS) generally improve over time.16,17 For instance, Banpurkar et al, found that while LV function initially declined post-closure, it generally returned to normal levels, with GLS showing strong correlation with LVEF and fractional shortening.16 Similarly, Elgayar et al, observed that LV function parameters initially worsened but improved significantly by the second follow-up.17 These findings underscore the typical recovery trajectory post-VSD closure but highlight the initial myocardial stress that may necessitate close monitoring.16,17 The clinical relevance of near-normal LVEF values remains debated. While LVEF often reaches or approaches normal ranges post-procedure, some studies suggest that significant systolic dysfunction can persist despite these seemingly normal values.18,19 Ali et al, noted that while overall LV systolic function improved, certain strain measures indicated ongoing myocardial dysfunction.18 This suggests that LVEF alone may not fully capture myocardial recovery, highlighting the need for advanced echocardiographic techniques.19

Residual lesions and their impact on LV function

The presence of residual lesions post-VSD closure varies among studies. Some report complete resolution of the defect, while others identify small residual shunts.20,21 For instance, the study by Bol-Raap et al observed a significant reduction in left ventricular hypertrophy following VSD closure, but noted the presence of trivial residual shunts in some patients.20 Despite the low incidence of pulmonary arterial hypertension (PAH), the persistence of residual lesions in some patients underscores the importance of ongoing follow-up to monitor potential complications.20,21

Comparative outcomes: surgical vs transcatheter closure

Comparative analyses between surgical and transcatheter VSD closure methods indicate that transcatheter techniques might offer better preservation of LV function. Studies show that patients undergoing transcatheter closure often have higher ejection fractions and reduced mitral regurgitation compared to those who have undergone surgical closure. For instance, Pawelec-Wojtalik et al found that the member VSD occluder method resulted in better LV systolic function and less mitral regurgitation compared to surgical repair.

These findings suggest that transcatheter closure may be preferable for preserving myocardial function, although individual patient factors should guide the choice of technique.22,23

Long-term outcomes and prognosis

Long-term follow-up studies generally indicate favorable outcomes, with most patients maintaining stable LV function after VSD closure.24,25 For example, Roos-Hesselink et al and Mythe et al reported that the majority of patients had normal LV dimensions and good functional status, with a small percentage experiencing residual defects or impaired function. These results reflect the overall effectiveness of both surgical and transcatheter techniques in achieving long-term recovery and stable cardiac function.24,25 This review faces limitations due to the heterogeneity in study designs, echocardiographic parameters, and follow-up durations.16,17,20

The variability in reported outcomes complicates direct comparisons and highlights the need for standardized reporting criteria. Furthermore, the clinical significance of near-normal LVEF values suggests a gap in current research, indicating the need for more sensitive diagnostic tools.19,22 Future research should focus on refining echocardiographic techniques and exploring long-term therapeutic strategies to optimize patient outcomes. Larger multicenter studies and standardized reporting will be crucial for advancing our understanding and improving care for this patient population.16,20,25

CONCLUSION

This review demonstrates that VSD closure generally leads to normal or near-normal LV function, with most patients showing recovery of LVEF and GLS over time. Although temporary declines in LV function are common immediately post-procedure, long-term outcomes are positive. Transcatheter closure may offer advantages in preserving myocardial function compared to surgical methods. However, subtle myocardial dysfunction and residual defects in some patients highlight the need for ongoing follow-up with advanced echocardiographic techniques to ensure optimal outcomes.

Funding: No funding sources

Conflict of interest: None declared

Ethical approval: Not required

REFERENCES

  1. 1. Hoffman JI, Kaplan S. The incidence of congenital heart disease. J Am Coll Cardiol. 2002;39(12):1890-900.
  2. 2. Rai SK, Yadav AK, Bhardwaj R, Kumar A, Lakhotia S, Mohapatra B, et al. Epidemiology of congenital heart disease in India. Congenit Heart Dis. 2014;10:437-46.
  3. 3. Baumgartner H, Bonhoeffer P, De Groot NM, et al. ESC Guidelines for the management of grown-up congenital heart disease (new version 2010). Eur Heart J. 2010;31(23):2915-57.
  4. 4. Kliegman RM, Stanton B, St. Geme J. Nelson Textbook of Pediatrics. Philadelphia, PA: Elsevier Inc. 2016;2(20):3888.
  5. 5. Lang RM, Badano LP, Mor-Avi V. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging. 2015;16(3):233-70.
  6. 6. Van der LD, Konings EE, Slager MA. Birth prevalence of congenital heart disease worldwide: a systematic review and meta-analysis. J Am Coll Cardiol. 2011;58(21):2241-7.
  7. 7. Veldtman GR, Connolly HM, Grogan M. Outcomes of contemporary surgical management of ventricular septal defect. Circulation. 2001;104(1):9.
  8. 8. Mertens L, Friedberg MK. Imaging the right ventricle current state of the art. Nat Rev Cardiol. 2010;7(10):551-63.
  9. 9. Muraru D, Spadotto V, Cecchetto A. New speckle-tracking algorithm for right ventricular volume analysis from three-dimensional echocardiographic data sets: validation with cardiac magnetic resonance and comparison with two-dimensional echocardiographic methods. J Am Soc Echocardiogr. 2016;29(4):310-21.
  10. 10. Hill KD, Jacobs JP, Bacha E. Outcomes and quality improvement in congenital heart surgery. Cardiol Young. 2008;18(2):143-8.
  11. 11. Piran S, Bassett AS, Grewal J. Outcome of repair of congenital heart disease in patients with the 22q11.2 deletion syndrome: a multicenter study. Circulation. 2008;118(22):2309-16.
  12. 12. Curtis JP, Sokol SI, Wang Y. The association of left ven- tricular ejection fraction, mortality, and cause of death in stable outpatients with heart failure. J Am Coll Cardiol. 2003;42:736-42.
  13. 13. Cikes M, Solomon SD. Beyond ejection fraction: an integrative approach for assessment of cardiac structure and function in heart failure. Eur Heart J. 2016;37:1642–50.
  14. 14. Moher D, Liberati A, Tetzlaff J, Altman DG; PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009;6(7):197.
  15. 15. Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021;372:71.
  16. 16. Banpurkar A, Azad S, Radhakrishnan S, Garg A. Left ventricular function assessment of patients with postoperative ventricular septal defect closure by longitudinal strain on two-dimensional echocardiography 1 year after surgery. J Indian Acad Echocardiogr Cardiovasc Imaging 2021;5:139-43.
  17. 17. Lasheen, Ahmed SS, Mahmoud K, Elgayar MM. Assessment of left ventricular systolic function after surgical and transcatheter device closure of ventricular septal defect using speckle tracking imaging. Menoufia Med J. 2023;36(3):11.
  18. 18. Ali YA, Hassan MA, El Fiky AA. Assessment of left ventricular systolic function after VSD transcatheter device closure using speckle tracking echocardiography. Egypt Heart J. 2019;71(1):1-7.
  19. 19. Quinn TA, Cabreriza SE, Blumenthal BF, Printz BF, Altmann K, Glickstein JS, et al. Regional functional depression immediately after ventricular septal defect closure. J Am Soc Echocardiogr. 2004;17(10):1066–72.
  20. 20. Hart JP, Cabreriza SE, Walsh RF, Printz BF, Blumenthal BF, Park DK, et al. Echocardiographic analysis of ventricular geometry and function during repair of congenital septal defects. Ann Thor Surg. 2004;77(1):53–60.
  21. 21. Bol-Raap G, Weerheim J, Kappetein AP, Witsenburg M, Bogers AJJC. Follow-up after surgical closure of congenital ventricular septal defect. Eur J Cardio-thoracic Surg. 2003;24(3):511-5.
  22. 22. Meijboom F, Szatmari A, Utens E, Deckers JW, Roelandt JR, Bos E, et al. Long-term follow-up after surgical closure of ventricular septal defect in infancy and childhood. J Am Coll Cardiol. 1994;24(5):1358–64.
  23. 23. Pawelec-Wojtalik M, Wojtalik M, Mrówczyński W, Surmacz R. Closure of perimembranous ventricular septal defect using transcatheter technique versus surgical repair. Kardiol Pol. 2005;63(6):595-602.
  24. 24. Roos-Hesselink JW, Meijboom FJ, Spitaels SE, Van Domburg R, Van Rijen EH, Utens EM, et al. Outcome of patients after surgical closure of ventricular septal defect at young age: longitudinal follow-up of 22-34 years. Eur Heart J. 2004;2(12):1057-62.
  25. 25. Menting ME, Cuypers JA, Opić P, Utens EM, Witsenburg M, van den Bosch AE, et al. The unnatural history of the ventricular septal defect: outcome up to 40 years after surgical closure. J Am Coll Cardiol. 2015;65(18):1941-51.