Case ReportInternational Journal of Research in Medical Sciences

Publication:
Use of magnetic port finder for metallic foreign body extraction in hand

Int J Res Med Sci. 2024;12(1):246-248.DOI10.18203/2320-6012.ijrms20234010

Thumbnail Image
View on the journal's website(opens in a new tab)

Abstract

Foreign bodies are defined as any foreign object that enters the human body due to various circumstances. FBs are a common reason for emergency department visits. The hand's complex vascular and nervous structures make aggressive exploration dangerous. FBs can be composed of various materials, making their detection with a single imaging study difficult. We propose using a magnetic tissue expander locator for intraoperative FB localization, presenting the case of a 50-year-old female patient who, after falling from her height, presented with a foreign body in her right hand. Due to the complexity of locating the FB, we used the magnetic finder, successfully extracting it without damaging any underlying structures. Use of magnetic tissue expander locators are effective, practical, and safe alternative to help for locating magnetic foreign bodies.

Keywords

Affiliations

  1. Department of Plastic and Reconstructive Surgery, Dr. Manuel Gea González General Hospital, México City, Mexico
  2. Hospital General 58 Instituto Mexicano del Seguro Social, México city, Mexico

Full item record