<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Original Research ArticleInternational Journal of Research in Medical Sciences

Publication:
Retrospective analysis of random and systematic errors in radiation therapy of head and neck cancer patients and its clinical predictive implications with VMAT treatment

Int J Res Med Sci. 2019;7(7):2758-2763.DOI10.18203/2320-6012.ijrms20192914

Thumbnail Image
View on the journal's website(opens in a new tab)

Abstract

Background The accuracy of radiotherapy is based on the matching of 2D portal/CBCT image with a reference image. The aim of this study is to determine the random and systematic setup errors (in cm) in radiotherapy of head and neck cancer patients and to derive the setup margin and its clinical implications.

Methods Author retrospectively reviewed the records of 25 head and neck cancer (HNC) patients treated with radiotherapy between Dec 2017 and July 2018. After immobilization, setup accuracy was assessed by registration of XVI image with planning reference image using Elekta XVI image guidance system and the isocenter correction was applied. For each patient 10 CBCT image sets were taken. The translational errors in X, Y and Z directions were used to estimate systematic (Σ) and random (σ) errors and to derive the final setup margin by using van Herk’s formula (2.5Σ + 0.7σ).

Results The mean translational errors ranges from -0.23 cm to 0.32 cm in Lateral (X), -0.15 to 0.16 cm in Longitudinal (Y) and -0.11 to 0.17 cm in vertical (Z) directions. The Mean and SD for systematic errors 0.21±0.13, 0.11±0.18, 0.14±0.11 and random error (in cm) are -0.03±0.33, 0.00±0.21 and 0.05±0.30 in X, Y and Z axis respectively. The final total margin for CTV to PTV including setup margin in the X, Y and Z directions (in cm) were 0.56, 0.61, and 0.47 respectively.

Conclusion Thus, the precise immobilization techniques are very important to reduce the setup margins, and the number of CBCTs during head and neck radiotherapy treatment.

Keywords

Affiliations

  1. Department of Radiotherapy Technologist, Nayati Healthcare and Research Centre, Mathura, Uttar Pradesh, India
  2. Department of Clinical Oncology, Nayati Healthcare and Research Centre, Mathura, Uttar Pradesh, India
  3. Department of Medical Physics, Nayati Healthcare and Research Centre, Mathura, Uttar Pradesh, India
  4. Department of Biostatistics, Nayati Healthcare and Research Centre, Mathura, Uttar Pradesh, India

Full item record