Background Dermatosis papulosa nigra (DPN) is a benign skin condition affecting predominantly individuals with Fitzpatrick skin type IV-VI. Electrosurgical treatment is cheaper and readily available, but optimal power settings remain undefined. The aim of this study is to compare the efficacy, safety, and cosmetic outcomes of high- versus low-power electrosurgery settings in the treatment of DPN.

Methods A split-face, evaluator-blinded, randomized controlled trial, 58 participants with Fitzpatrick skin types IV–VI underwent treatment using both high-power and low-power electrosurgical settings (each set at 9 Watts) on opposite sides of the face or neck. Outcomes—lesion clearance, scarring, and pigmentation—were assessed via standardized photography two weeks post-procedure by blinded dermatologists.

Results High-power settings resulted in higher lesion clearance (82.8% versus 77.6%, p 85%) with minimal cosmetic side effects, did not differ significantly between groups (p=0.56).

Conclusions Although, low-power setting electrosurgery of DPN offers comparable efficacy to high-power settings, it may require more treatment cycles to eliminate all lesions. It is also the preferable setting for individuals prone to scarring or pigmentary changes.