Original Research ArticleInternational Journal of Basic & Clinical Pharmacology
Publication: In-vitro study of quality control parameters of three different brands of azithromycin tablets
Int J Basic Clin Pharmacol. 2017;6(7):1572-1576.DOI10.18203/2319-2003.ijbcp20172548
Abstract
Background Azithromycin, being a very important antibiotic, is manufactured by different pharmaceutical companies and available in numerous brands. Therefore, it requires a quantitative evaluation and assessment of tablets chemical, physical and bioavailability properties.
Methods The physicochemical quality pararametrs like weight variation, size, hardness, friability, disintegration time and dissolution profile of three brands of azithromycin tablets were assessed by performing various test procedures according to established methods.
Results The different brands of tablets showed very slight variations in weight and size, not exceeding more than 5% of standard value. Similarly, hardness of all the brands was less than 5kg/f and friability ranged from 0.2 to 0.5%. All the brands tested disintegrated in 75% of the active ingredient within 45 minutes.
Conclusions All the physiochemical quality parameters of three brands of azithromycin tablets were found to be within the pharmacopeial specifications therefore all the brands were pharmaceutically and chemically equivalent and can be freely interchanged.
Keywords
Affiliations
- Department of Pharmacology, Rajshree Medical Research Institute, Bareilly, Uttar Pradesh, India
- Department of Pharmacy, Mahatama Jyotiba Phule Rohilkhand University, Bareilly, Uttar Pradesh, India
- Department of Pharmacology, Shri Ram Murti Smarak Institute of Medical Sciences, Bareilly, Uttar Pradesh, India