Abstract
Pulmonary artery catheter (PAC) or Swan-Ganz catheter is a flow directed balloon tipped catheter routinely used in patients undergoing Coronary Artery Bypass Grafting (CABG). The reported rate of complications with PAC is 3-17% including arrhythmias, pneumothorax, pulmonary embolism, bacteraemia and death1. Knot formation is an uncommon complication of PAC and is usually managed conservatively2. Here we report about a patient with knotted PAC who required operative intervention after failure of conventional measures as the knot engulfed the tricuspid valve chordae and was fixed.
Keywords
Affiliations
- Department of Cardiothoracic and Vascular Surgery, P.G.I.M.E.R and Dr. RML Hospital, New Delhi, India