Original Research ArticleInternational Journal of Contemporary Pediatrics

Publication:
Correlation of transcutaneous bilirubin with total serum bilirubin in neonates with hyperbilirubinemia

Int J Contemp Pediatr. 2021;8(7):1256-1259.DOI10.18203/2349-3291.ijcp20212322

Read online (HTML) View on the journal's website(opens in a new tab)

Abstract

Background For determining hyperbilirubinemia in a neonate, clinical evaluation, serum bilirubin estimation and trans cutaneous bilirubin estimation are the modalities available. Transcutaneous bilirubinometry (TcB) is routinely used to monitor jaundice in term and near-term infants. Literature shows a positive correlation observed between TcB and total serum bilirubin (TSB). The present study was conducted determine the correlation of TcB with TSB in neonates with hyperbilirubinemia admitted at a tertiary care hospital, ChennaiMethods: A cross sectional study was conducted at a tertiary care hospital, Chennai where 350 neonates who have clinical jaundice and require estimation of serum bilirubin who are admitted to the tertiary care centre, Chennai during December 2020-March 2021 were included in the study. The ROCHE INTEGRA-e 411+ autoanalyzer was used to estimate TSB (mg/dl) using a modified diazo method. The Jaundice Meter JM-103 to measure TcB, (Manufactured by Draeger medical systems, Germany). Pearson corelation coefficient was used to find the correlation between the two variables. P<0.05 was considered to be statistically significant.

Results Out of 350 neonates admitted to the tertiary care centre, term deliveries were 57.1% and pre term were 42.9%. 83.1% were in the age group of 3-7 days. The mean weight of the study population was 2.16±0.60 kg. In term babies, Pearson corelation between TSB and TcB shows a statistically significant positive correlation, r=0.90 with p≤0.0001. Among pre term babies, Pearson corelation between TSB and TcB shows a statistically significant positive correlation, r=0.96 with p≤0.0001.

Conclusions This study's findings support the use of a TcB metre as a screening tool for clinically significant hyperbilirubinemia.

Keywords

Affiliations

  1. Department of Paediatrics, Shri Sathya Sai Medical College and Research Institute, Ammapettai, Kancheeepuram, Nellikuppam, Tamil Nadu, India
  2. Department of Paediatrics, ESIC medical college and PGIMSR, Chennai, Tamil Nadu, India

Full item record