Original Research ArticleInternational Journal of Research in Orthopaedics

Publication:
Prospective observational study evaluating the outcome of a fixed angle plate (proximal humerus internal locking system) in proximal humerus fractures

Int J Res Orthop. 2020;6(1):117-122.DOI10.18203/issn.2455-4510.IntJResOrthop20195804

Thumbnail Image
Read online (HTML) View on the journal's website(opens in a new tab)

Abstract

Background Proximal humerus fractures are common among elderly. The present study assesses the functional outcomes of fixed angle plate (proximal humerus internal locking system (PHILOS)) in fractures of proximal humerus.

Methods 30 participants aged ≥18 years with proximal humerus fracture (2, 3 and 4 part) who underwent PHILOS fixation were enrolled. Undisplaced, open, severely comminuted, metastatic, and pathological fractures and with associated head injury and neurovascular injuries wew excluded. Clinical and radiological evaluation were done pre and post-operatively. Intraarticular extent of fracture geometry was assessed using 3-dimensional computed tomography. Participants were managed preoperatively with analgesics and shoulder immobilizer followed by preanesthetic check-up and routine investigations and surgery was done once participants were stable. Sample size was calculated assuming excellent or satisfactory results in 80% participants 6 months after surgery, relative precision of 20%, α of 5% and 10% attrition rate. Institutional ethics committee approved the study and written informed consent was obtained from all study participants.

Results Mean age of study participants was 62.9 (14.9) years and were predominantly females (66.6%, n=20). No significant difference between type of fracture and duration of recovery was observed (p=0.4). 30% participants had post-operative complications, stiffness was the most common (13.3%, n=4) complication. 76.6% (n=23) participants had good functional outcomes. Significant correlation between type of fracture and NEER score was observed (p<0.0001).

Conclusions PHILOS is a preferential implant in proximal humerus fractures due to angular stability, particularly in comminuted fractures in younger patients, and osteoporotic fractures in elderly, thus allowing early mobilization and satisfactory final functional outcome.

Keywords

Affiliations

  1. Department of Orthopaedics, Pushpagiri Institute of Medical Sciences, Thiruvalla, Kerala, India

Full item record