Case ReportInternational Journal of Research in Orthopaedics

Publication:
Neck fluid extravasation in shoulder arthroscopic surgery-a life-threatening complication: a report of two cases

Int J Res Orthop. 2024;10(1):178-181.DOI10.18203/issn.2455-4510.IntJResOrthop20234060

Thumbnail Image
Read online (HTML) View on the journal's website(opens in a new tab)

Abstract

Fluid extravasation in shoulder arthroscopy may lead to life-threatening consequences, such as airway compromise. These cases are rare and few were reported in the literature. Clinical cases of 2 female patients submitted to shoulder arthroscopy for a rotator cuff tear repair, complicated with fluid extravasation that led to trachea compression and need for intensive care unit (ICU) admission with postponed extubation. Neither patients showed any sequelae in the follow-up period. Report of these rare complications, with detailed and reproducible information, is vital for their comprehension and future elaboration of surveillance and treatment guidelines.

Keywords

Affiliations

  1. Department of Orthopedics and Traumatology of Centro Hospitalar Trás-os-Montes e Alto Douro, Rua dos Lagoeiros 43, Vila Real, Portugal